OCZ FATAL1TY Series 1000 W 8

OCZ FATAL1TY Series 1000 W

Transient Response Tests »

Cross Load Tests

For the generation of the following charts we set our loaders in auto mode, through our custom software, and try over a thousand possible load combinations with +12V, 5V and 3.3V rails. The voltage regulation deviations in each of the below charts are calculated taking the nominal values of the rails (12V, 5V and 3.3V) as point zero. We should note here that we will run this test only with PSUs that have capacity equal or lower than 1000W since it takes way too long and as the capacity increases the completion time increases exponentially.

+12V Voltage Regulation Chart

5V Voltage Regulation Chart

3.3V Voltage Regulation Chart

Efficiency Chart

+12V Ripple Chart

5V Ripple Chart

3.3V Ripple Chart

5VSB Ripple Chart

Next Page »Transient Response Tests