Super Flower Golden Silent 500 W Review 3

Super Flower Golden Silent 500 W Review

Value & Conclusion »

Ripple Measurements

In the following table you will find the ripple levels that we measured on the main rails of SF-500P14FG. According to ATX specification the limits are 120 mV (+12V) and 50 mV (5V, 3.3V and 5VSB).

Ripple Measurements
Super Flower SF-500P14FG
Test12 V5 V3.3 V5VSBPass/Fail
20% Load11.2 mV8.6 mV7.4 mV5.2 mVPass
40% Load13.2 mV9.2 mV8.6 mV5.8 mVPass
50% Load14.2 mV9.2 mV9.2 mV6.4 mVPass
60% Load15.0 mV9.8 mV10.6 mV6.8 mVPass
80% Load18.2 mV11.2 mV13.4 mV8.0 mVPass
100% Load21.8 mV14.8 mV19.4 mV9.6 mVPass
120% Load27.8 mV17.0 mV21.8 mV11.0 mVPass
Crossload 114.8 mV15.8 mV17.8 mV6.2 mVPass
Crossload 218.2 mV10.2 mV12.6 mV7.0 mVPass

Ripple/noise suppression is very good and even when we overpowered the PSU to 600W we didn't notice any dramatic increases in ripple. This clearly shows that Super Flower paid extra attention to ripple filtering and the result is definitely noteworthy.

Ripple at Full Load

In the following oscilloscope screenshots you can see the AC ripple and noise that the main rails registered (+12V, 5V, 3.3V and 5VSB). The bigger the fluctuations on the oscilloscope's screen the bigger the ripple/noise. For all measurements we set 0.02 V/Div (each vertical division/box equals to 0.02V) as standard.



Ripple at 120% load



Ripple at Crossload 1



Ripple at Crossload 2