Chieftec Polaris 1050 W Review 2

Chieftec Polaris 1050 W Review

Fan Noise »

Efficiency

Using the results we gathered so far, we plotted a chart showing the PSU's efficiency at low loads and loads ranging from 10 to 110 percent of the maximum-rated capacity.




This platform operates very efficiently, especially at light loads.

10%–110% Load Testing

These tests reveal the PSU's load regulation and efficiency levels under high ambient temperatures and show how the fan-speed profile behaves under harsh operating conditions.

Load Regulation & Efficiency Testing Data - Chieftec Polaris 1050W
Test12V5V3.3V5VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoiseTemp
(In/Out)
PF/AC
Volts
10%6.878A1.973A1.987A0.984A104.948W89.45%0 RPM<6.0 dB(A)45.53°C0.862
12.117V5.069V3.321V5.081V117.329W40.55°C230.33V
20%14.788A2.963A2.983A1.185A209.934W92.791%0 RPM<6.0 dB(A)46.06°C0.944
12.107V5.062V3.319V5.065V226.245W40.73°C230.33V
30%23.078A3.461A3.485A1.386A314.936W93.28%660 RPM15 dB(A)41.35°C0.97
12.085V5.056V3.314V5.049V337.627W47.29°C230.33V
40%31.352A3.96A3.988A1.59A419.561W93.382%848 RPM23.8 dB(A)41.72°C0.981
12.068V5.051V3.31V5.033V449.297W48.1°C230.34V
50%39.339A4.957A4.99A1.794A524.886W93.249%851 RPM23.8 dB(A)41.95°C0.988
12.058V5.044V3.307V5.016V562.886W48.88°C230.34V
60%47.275A5.956A5.994A2A629.415W92.894%1021 RPM29.6 dB(A)42.26°C0.992
12.049V5.037V3.303V4.999V677.561W49.85°C230.34V
70%55.289A6.959A6.999A2.207A734.724W92.356%1311 RPM36.8 dB(A)43.17°C0.994
12.039V5.031V3.301V4.982V795.535W51.29°C230.34V
80%63.309A7.964A8.002A2.315A839.559W91.881%1434 RPM39.6 dB(A)44.29°C0.995
12.031V5.024V3.298V4.967V913.74W52.83°C230.34V
90%71.748A8.467A8.495A2.422A944.938W91.393%1526 RPM41.3 dB(A)44.88°C0.997
12.021V5.019V3.295V4.953V1033.929W53.88°C230.34V
100%79.923A8.975A9.018A3.047A1049.769W90.728%1769 RPM45.7 dB(A)45.59°C0.998
12.012V5.014V3.293V4.922V1157.045W55.41°C230.35V
110%87.970A9.984A10.116A3.055A1154.395W90.122%1761 RPM45.5 dB(A)46.84°C0.997
12.005V5.008V3.291V4.909V1280.93W57.73°C230.35V
CL10.115A14.37A14.339A0A121.292W84.056%0 RPM<6.0 dB(A)49.19°C0.899
12.112V5.025V3.326V5.09V144.3W42.34°C230.37V
CL20.114A22.002A0A0A111.394W81.242%0 RPM<6.0 dB(A)51.5°C0.89
12.121V5V3.331V5.099V137.115W43.43°C230.37V
CL30.114A0A21.709A0A73.976W76.709%0 RPM<6.0 dB(A)53.71°C0.821
12.124V5.073V3.344V5.096V96.437W44.71°C230.37V
CL487.316A0A0.001A0.003A1049.578W91.357%1650 RPM43.7 dB(A)45.17°C0.998
12.020V5.053V3.303V5.027V1148.879W55.17°C230.34V

This PSU's fan doesn't exceed 1000 RPM at up to the 50% load, which has output noise stay low despite high operating temperatures. Moreover, the platform delivers 110% of its maximum-rated load at 47°C for a prolonged period of time without any problems. Still, overloading this or any other PSU is not advisable, especially under increased operating temperatures; doing so will notably shorten its expected lifespan even if it survives.

Light Load Testing

In the following tests, we measure the PSU's efficiency at loads significantly lower than 10 percent of the maximum capacity—the lowest load the 80 PLUS standard measures. This is important for when a PC is idle with its power-saving features turned on.

Light Load Efficiency - Chieftec Polaris 1050W
Test12V5V3.3V5VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoiseTemp
(In/Out)
PF/AC
Volts
20W1.226A0.493A0.497A0.196A19.992W70.64%0 RPM<6.0 dB(A)39.07°C0.473
12.110V5.076V3.321V5.115V28.301W36.83°C230.33V
40W2.699A0.69A0.696A0.293A39.993W80.976%0 RPM<6.0 dB(A)40.65°C0.657
12.110V5.074V3.321V5.11V49.388W37.83°C230.33V
60W4.170A0.887A0.894A0.392A59.993W85.512%0 RPM<6.0 dB(A)42.25°C0.742
12.117V5.073V3.321V5.105V70.157W38.62°C230.33V
80W5.638A1.084A1.093A0.49A79.941W88.07%0 RPM<6.0 dB(A)43.84°C0.802
12.117V5.072V3.321V5.1V90.769W39.77°C230.33V
100W7.110A1.282A1.292A0.589A99.938W89.559%0 RPM<6.0 dB(A)43.85°C0.855
12.116V5.071V3.321V5.095V111.588W39.82°C230.33V

Efficiency levels are high at light loads, and the PSU's fan doesn't spin up, so output noise is close to zero.

Ultra-Light Load Testing

The applied load in this test is only 10 W for PSUs with 500 W and less capacity. We dial in 2% of the maximum-rated capacity for all other PSUs and only run this test with 115 V input.

Super-Light Load Efficiency - Chieftec Polaris 1050W
12V5V3.3V5VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoiseTemp
(In/Out)
PF/AC
Volts
1.538A0.252A0.255A0.052A20.99W71.31%0 RPM<6.0 dB(A)28.69°C0.845
12.093V5.073V3.316V5.121V29.435W21.96°C115.11V

The PSU exceeds the 70% efficiency mark with 2% load.

5VSB Efficiency

5VSB Efficiency - Chieftec Polaris 1050W
Test #5VSBPower
(DC/AC)
EfficiencyPF/AC Volts
10.1A0.512W72.707%0.024
5.122V0.704W230.28V
20.25A1.279W78.625%0.055
5.118V1.627W230.28V
30.55A2.809W81.132%0.112
5.109V3.462W230.28V
41A5.095W81.954%0.182
5.096V6.217W230.28V
51.5A7.621W81.953%0.241
5.081V9.299W230.28V
62.999A15.105W81.345%0.338
5.036V18.569W230.28V


The 5VSB rail is highly efficient.

Power Consumption in Idle and Standby

Idle / Standby - Chieftec Polaris 1050W
Mode12V5V3.3V5VSBPower (AC)PF/AC Volts
Idle12.043V5.067V3.307V5.126V5.448W0.161
230.29V
Standby0.122W0.004
230.29V


Power consumption could be lower, ideally below 0.1 W with 230 V input.
Next Page »Fan Noise
View as single page
Jun 16th, 2024 07:58 EDT change timezone

New Forum Posts

Popular Reviews

Controversial News Posts