Noise and Fan Speed (Increased Temperatures)

Fan speed increases linearly with up to 1200 W loads and tops out once the load reaches 1600 W and operating temperature exceeds 45°C.



Noise and Fan Speed (~30 °C)

Fan noise is kept below 25 dBA with up to 810 W load at normal operating temperatures. The 30 dBA mark is exceeded with 880 W, and 40 dBA with 1405 W. With more than 1730 W, fan noise exceeds 45 dBA.