Enermax REVOLUTION D.F. 12 850 W Review 9

Enermax REVOLUTION D.F. 12 850 W Review

Value & Conclusion »

Result Summary

Test results (AC @ 230 V) - Enermax REVOLUTION D.F. 12 850 W
Test12 V5 V3.3 VPower
(DC/AC)
EfficiencyFan spinning?Noise levelTemp
(In/Out)

Power Factor

5 %2.81 A1.02 A1.03 A42.96 W85.74 %No26.8 dBA40.7 °C0.73
12.21 V5.091 V3.360 V50.11 W39.8 °C
10 %5.87 A1.70 A1.73 A86.03 W90.00 %No26.8 dBA39.3 °C0.86
12.20 V5.078 V3.344 V95.59 W40.0 °C
20 %12.31 A2.57 A2.60 A171.57 W92.32 %No26.8 dBA39.6 °C

0.94

12.18 V5.055 V3.325 V185.84 W41.2 °C
30 %19.10 A3.01 A2.97 A256.88 W92.69 %No26.8 dBA39.8 °C0.97
12.14 V5.040 V3.325 V277.14 W41.4 °C
40 %26.03 A3.48 A3.46 A344.10 W92.81 %924 RPM31.2 dBA41.1 °C0.98
12.11 V5.022 V3.296 V370.75 W41.7 °C
50 %32.59 A4.38 A4.34 A429.81 W92.55 %924 RPM31.2 dBA41.0 °C0.98
12.08 V4.998 V3.279 V464.42 W42.0 °C
60 %39.15 A5.30 A5.26 A514.83 W91.91 %926 RPM31.3 dBA42.3 °C0.98
12.04 V4.969 V3.257 V560.16 W43.3 °C
70 %45.75 A6.22 A6.18 A599.80 W91.23 %1286 RPM34.3 dBA41.6 °C0.98
12.00 V4.942 V3.246 V657.45 W42.4 °C
80 %52.95 A6.42 A6.45 A686.35 W90.32 %1637 RPM42.2 dBA41.2 °C0.98
11.97 V4.929 V3.239 V759.89 W43.1 °C
90 %59.75 A7.27 A7.32 A773.34 W90.20 %1858 RPM44.8 dBA40.1 °C0.98
11.95 V4.903 V3.239 V859.76 W43.7 °C
100 %66.73 A8.11 A7.64 A860.97 W89.29 %2106 RPM49.2 dBA40.5 °C0.98
11.94 V4.882 V3.222 V964.14 W44.2 °C
110 %73.77 A8.99 A8.48 A948.11 W88.70%2192 RPM50.6 dBA40.9 °C0.98
11.89 V4.866 V3.212 V1068.69 W44.8 °C

The REVOLUTION D.F. 12 850 W passes all load tests with no issues. There are, however, a few things to note right away. While the PSU remains passive in the first few tests, we can see the fan begin spinning at 40 % load. While this is not a significant deviation from the vendor-provided 50 % mark, the more noteworthy thing is the fairly rapid increase in the corresponding acoustic levels. Until the 70 % load mark the PSU remains barely audible. However, moving beyond this mark the RPM and fan noise spike is less subtle. Again, this by no means represents a typical use case for the PSU, but at high loads in a high ambient temperature the REVOLUTION D.F. 12 850 W can become noisy.



When it comes to efficiency, the D.F. 12 850 W shows very good results, easily surpassing the 80 Plus Gold requirements, yet falling short of reaching Platinum efficiency levels. For this class we see great efficiencies at very low loads (over 90 % efficiency at 10 % load). The maximum efficiency we have observed in 230 V mains was over 92.8 %, which, while falling short for the maximum efficiency levels of 80 Plus Platinum units, at high ambient temperatures is very impressive. Even at >110 % loads we see efficiency remain close to 89 %.

Voltage Regulation

Voltage regulation - Enermax REVOLUTION D.F. 12 850 W
Test+12 V+5 V+3.3 V
5 %1.75 %1.82 %1.82 %
10 %1.67 %1.56 %1.33 %
20 %1.50 %1.10 %0.76 %
30 %1.17 %0.80 %0.36 %
40 %0.92 %0.44 %-0.12 %
50 %0.67 %-0.04 %-0.64 %
60 %0.33 %-0.62 %-1.30 %
70 %0 %-1.16 %-1.64 %
80 %-0.25 %-1.42 %-1.85 %
90 %-0.42 %-1.94 %-1.94 %
100%-0.50 %-2.36 %-2.36 %
110 %-0.92 %-2.68 %-2.67 %







In terms of voltage regulation, while we are far away from the maximum deviations allowed by the ATX spec, we have definitely seen better results over the past year. Nonetheless, we can still classify the +12 V results as very good with very little deviation at medium to high loads. The minor rails could be controlled more tightly, as they approach the 2.5 % mark at full load.

Ripple

Ideally you want the DC voltage delivered by your power supply to be a completely flat line when looking through an oscilloscope. However, due to the switching nature of ATX power supplies and the less than ideal real world behavior of all the components involved, we get very small fluctuations in output voltage, known as ripple and noise. The ATX spec allows a ripple of up to 120 mV for the +12 V rail and 50 mV for the minor rails.

Ripple - Enermax REVOLUTION D.F. 12 850 W
Test12 V5 V3.3 V
5 %14 mV18 mV14 mV
10 %16 mV18 mV16 mV
20 %16 mV20 mV16 mV
30 %18 mV20 mV18 mV
40 %20 mV22 mV18 mV
50 %22 mV22 mV18 mV
60 %22 mV24 mV18 mV
70 %24 mV24 mV18 mV
80 %24 mV24 mV18 mV
90 %24 mV24 mV20 mV
100%24 mV26 mV20 mV
110 %26 mV26 mV20 mV

The ripple control for this PSU is very good with sub 30 mV peak-to-peak values on all rails even in the overload tests.

Below you can find an image of the ripple recorded at 110% of the PSU load.



Short Circuit Protection

Short circuit protection is one of the most fundamental and important protections for a power supply. If a short circuit is detected on any rails, the PSU should turn off and prevent damage to itself and other components.

Short Circuit Protection
+12 V railOperational
+5 V railOperational
+3.3 V railOperational

SCP worked as expected with the unit.