Result Summary

Full-Range Load Testing (230 V)
All-rail
Load
12 V5 V3.3 VPower
(DC/AC)
EfficiencyFan
Speed
Noise
Level
Power
Factor
0 %0 A4.00 A6.06 A0.00 W0.00 %Fan Stop0.10
11.99 V5.01 V3.30 V3.90 W
5 %1.67 A4.00 A6.06 A60.00 W82.99 %Fan Stop0.70
12.03 V5.09 V3.38 V72.30 W
10 %6.67 A4.00 A6.06 A120.00 W88.24 %Fan Stop0.84
12.02 V5.09 V3.38 V136.00 W
20 %16.67 A4.00 A6.06 A240.00 W91.64 %Fan Stop0.92
12.00 V5.09 V3.38 V261.90 W
30 %26.67 A4.00 A6.06 A360.00 W92.28 %Fan Stop0.94
11.99 V5.09 V3.38 V390.10 W
40 %36.67 A4.00 A6.06 A480.00 W92.75 %Fan Stop0.95
11.97 V5.09 V3.39 V517.50 W
50 %46.67 A4.00 A6.06 A600.00 W92.84 %861 RPM27.4 dBA0.96
11.95 V5.10 V3.39 V646.25 W
60 %56.67 A4.00 A6.06 A720.00 W92.57 %882 RPM27.8 dBA0.97
11.93 V5.10 V3.39 V777.80 W
70 %66.67 A4.00 A6.06 A840.00 W91.88 %891 RPM28.0 dBA0.97
11.91 V5.10 V3.39 V914.20 W
80 %76.67 A4.00 A6.06 A960.00 W91.52 %1045 RPM30.2 dBA0.97
11.89 V5.10 V3.39 V1049.00 W
90 %86.67 A4.00 A6.06 A1080.00 W91.29 %1157 RPM31.3 dBA0.98
11.87 V5.10 V3.39 V1183.00 W
100 %96.67 A4.00 A6.06 A1200.00 W90.29 %1750 RPM36.4 dBA0.98
11.85 V5.10 V3.39 V1329.00 W
110 %106.67 A4.00 A6.06 A1320.00 W89.73 %2048 RPM42.8 dBA0.98
11.83 V5.10 V3.39 V1471.00 W

Efficiency





The efficiency comfortably meets the requirements for its 80 Plus Gold rating, even at 230 V which is a superb result, as many 115 V rated units fail to fully hit the same rating at 230 V.

Rated Efficiency Validation (230 V)
Certification: 80 Plus Gold
Test LoadRequiredMeasuredMarginStatus
20%90.00 %91.64 %+1.64 %Pass
50%92.00 %92.84 %+0.84 %Pass
100%89.00 %90.29 %+1.29 %Pass

Fan Noise


The fan came on shortly after a 40% load was applied, as expected, and gradually ramped up in speed as the temperatures inside the supply increased. By 100% load and beyond, the fan was noticeable but without a harsh noise profile, and it did not react too quickly to changes in load, which can be an annoying behavior.

Voltage Regulation

Voltage Regulation & ATX 3.1 Compliance
Test LoadRailMeasuredATX 3.1 Spec LimitMarginStatus
Idle (0%)+12V11.99 V+5% / -7% (11.16 V to 12.60 V)-0.08 %Pass
+5V5.01 V±5% (4.75 V to 5.25 V)+0.20 %Pass
+3.3V3.30 V±5% (3.14 V to 3.47 V)0.00 %Pass
100% Load+12V11.85 V+5% / -7% (11.16 V to 12.60 V)-1.25 %Pass
+5V5.10 V±5% (4.75 V to 5.25 V)+2.00 %Pass
+3.3V3.39 V±5% (3.14 V to 3.47 V)+2.73 %Pass

All rails are regulated well within ATX limits; you can see the minor DC-DC rails actually increase in voltage as the switching mode changes with the increased load. It would benefit from the 12 V rail starting a touch higher to negate voltage drop across the cables under load.

Cable Quality

Although voltage regulation inside modern PSUs is (usually) extremely stable, voltage drop and thus power losses will occur across the cables as current is drawn through them. This results in a lower voltage available to the system components than what is actually measured at the PSU outputs. Thicker cables will cause less voltage drop and more power to the components. Any power lost across the cables is wasted as heat in the wire itself. By measuring the voltage drop at a known load, we can calculate the resistance of the cables.

Cable Losses at Full Load
Applied 12 V Load106.67 A
Measured @ Supply11.99 V
Measured @ Load11.83 V
Power Lost in Cable17.06 W
Per-Cable Resistance69.00 mΩ
Cable Temperature27.8 °C







The cables are of very reasonable quality, with a fairly low resistance and not too much power is lost across them as a result. We did notice that the PSU connector side was getting much hotter than the load end, meaning most of the losses were occurring actually before the main cable length.

Testing the 12V2X6 cable alone with a fixed 600 W load, we saw a wire resistance of 72 mΩ which is within margin of error of the 69 mΩ measured using all cables, meaning current sharing is quite balanced. The wire and connector temperature stayed under 28 C after sustained load.



Ripple

Ideally you want the DC voltage delivered by your power supply to be a completely flat line when looking through an oscilloscope. However, due to the switching nature of the ATX power supply and the less than ideal real world behavior of all the components involved, we get very small fluctuations in the voltage output, known as ripple and noise. The ATX spec allows a ripple of up to 120 mV for the +12 V rail and 50 mV for the minor rails (measured in mV P-P).

Ripple (mV P-P)
Test Load12 V5 V3.3 VStatus
10%19.57 mV13.15 mV11.74 mVPass
20%23.05 mV13.63 mV12.45 mVPass
30%25.68 mV14.99 mV13.44 mVPass
40%27.38 mV16.55 mV14.42 mVPass
50%29.36 mV17.54 mV15.98 mVPass
60%32.30 mV19.09 mV17.11 mVPass
70%34.82 mV20.08 mV18.24 mVPass
80%37.11 mV22.06 mV19.66 mVPass
90%38.41 mV23.62 mV20.93 mVPass
100%39.54 mV25.17 mV22.20 mVPass
110%41.44 mV26.73 mV23.76 mVPass



The ripple across all rails is controlled and well within ATX specification. I was expecting to see poorer results here, given the voltage sag and sparse layout, but this is performing perfectly in line with the majority of other similar and even higher grade models.


Short Circuit Protection

Short circuit protection is one of the most fundamental and important protections for a power supply. If a short circuit is detected on any rails, the PSU should turn off and prevent damage to itself and other components.

Short Circuit Protection
+12 V railOperational
+5 V railOperational
+3.3 V railOperational

SCP was working as expected with the unit.