FSP MEGA PM 1200W Review 2

FSP MEGA PM 1200W Review

Value & Conclusion »

Result Summary

Full-Range Load Testing (230 V)
All-rail
Load
12 V5 V3.3 VPower
(DC/AC)
EfficiencyFan
Speed
Noise
Level
Power
Factor
0 %0 A4.00 A6.06 A0.00 W0.00 %Fan Stop0.20
12.10 V5.11 V3.40 V8.00 W
5 %1.67 A4.00 A6.06 A60.00 W81.74 %Fan Stop0.75
12.10 V5.11 V3.40 V73.40 W
10 %6.67 A4.00 A6.06 A120.00 W87.34 %Fan Stop0.89
12.09 V5.11 V3.40 V137.40 W
20 %16.67 A4.00 A6.06 A240.00 W91.01 %Fan Stop0.95
12.08 V5.11 V3.39 V263.70 W
30 %26.67 A4.00 A6.06 A360.00 W91.77 %Fan Stop0.97
12.07 V5.11 V3.39 V392.30 W
40 %36.67 A4.00 A6.06 A480.00 W92.36 %Fan Stop0.98
12.06 V5.11 V3.39 V519.70 W
50 %46.67 A4.00 A6.06 A600.00 W92.54 %Fan Stop0.98
12.05 V5.11 V3.39 V648.35 W
60 %56.67 A4.00 A6.06 A720.00 W92.34 %643 RPM26.2 dBA0.98
12.04 V5.10 V3.39 V779.75 W
70 %66.67 A4.00 A6.06 A840.00 W92.27 %683 RPM26.2 dBA0.98
12.03 V5.10 V3.39 V910.40 W
80 %76.67 A4.00 A6.06 A960.00 W91.87 %740 RPM26.3 dBA0.98
12.02 V5.10 V3.38 V1045.00 W
90 %86.67 A4.00 A6.06 A1080.00 W91.60 %815 RPM27.5 dBA0.98
12.01 V5.10 V3.38 V1179.00 W
100 %96.67 A4.00 A6.06 A1200.00 W90.77 %900 RPM28.6 dBA0.98
12.00 V5.10 V3.38 V1322.00 W
110 %106.67 A4.00 A6.06 A1320.00 W90.47 %998 RPM30.2 dBA0.98
11.99 V5.10 V3.38 V1459.00 W

Efficiency




This supply is rated as 80 Plus Platinum; however, this will be based on the 115 V measurements. FSP do not provide an 80 Plus rating at 230 V, so we will compare the measurements to the 80 Plus Platinum (230 V) standard.

Rated Efficiency Validation (230 V)
Certification: 80 Plus Platinum
Test LoadRequiredMeasuredMarginStatus
20%92.00 %91.01 %-0.99 %
50%94.00 %92.54 %-1.46 %
100%90.00 %90.77 %+0.77 %Pass

Testing at 230 V (closer to 240 V in reality), the results fall a touch short of a Platinum rating at low and mid-loads, and would come under a Gold rating. This is still a very respectable result though from a 1200 W model in this price range. Power factor is good, but not as high as we have seen on devices using more modern and sophisticated controllers.

Fan Noise


The fan blade profile coupled with the low speeds result in a wonderfully quiet experience even pushed beyond 100% load. Heavy loads were maintained for a prolonged period and the fan never ramped up beyond 1000 RPM, remaining near silent the entire time.


An interesting point worth mentioning is that during the initial test, the fan never started spinning, even at 100% load, despite the temperatures inside exceeding 100 C. The ECO switch was toggled, and the unit powered off and back on again. Only then did the fan begin spinning at around a 60% load.

Voltage Regulation

All ATX PSUs have a voltage regulation feedback loop, which increases the PWM duty cycle for each rail to account for voltage drop when current is drawn. However, most PSUs only measure voltage at the PSU output, rather than at the end of the cable going to the load. This means any voltage drop across the cable is not automatically adjusted for. The ATX 3.1 specification outlines a maximum allowed voltage drop at the load itself to ensure system stability.

Voltage Regulation & ATX 3.1 Compliance
Test LoadRailMeasuredATX 3.1 Spec LimitMarginStatus
Idle (0%)+12V12.10 V+5% / -8%+0.83 %Pass
+5V5.11 V±5%+2.20 %Pass
+3.3V3.40 V±5%+2.12 %Pass
100% Load+12V12.00 V+5% / -8%0.00 %Pass
+5V5.10 V±5%+2.00 %Pass
+3.3V3.38 V±5%+1.52 %Pass


Both the low-voltage rails are set a touch high but well within limits, and the 12 V rail settles to dead on 12 V by 100% load after losses across the cables. A very reasonable result.

Cable Quality

Although voltage regulation inside modern PSUs is extremely stable, voltage drop and thus power losses will occur across the cables as current is drawn through them. This results in a lower voltage available to the system components than what is actually measured at the PSU outputs. Thicker cables will cause less voltage drop and more power to the components. Any power lost across the cables is wasted as heat in the wire itself. By measuring the voltage drop at a known load, we can calculate the resistance of the cables.

Cable Losses at Full Load
Applied 12 V Load106.67 A
Measured @ Supply12.08 V
Measured @ Load11.99 V
Power Lost in Cable9.60 W
Per-Cable Resistance38.81 mΩ
Cable Temperature24.5 °C





The cables FSP have included have a nice low resistance with good connection quality, and quite even current sharing between cables.

Ripple

Ideally you want the DC voltage delivered by your power supply to be a completely flat line when looking through an oscilloscope. However, due to the switching nature of the ATX power supply and the less than ideal real world behaviour of all the components involved, we get very small fluctuations in the voltage output, known as ripple and noise. The ATX spec allows a ripple of up to 120 mV for the +12 V rail and 50 mV for the minor rails.

Ripple (mV)
Test Load12 V5 V3.3 VStatus
5%11 mV8 mV9 mVPass
10%13 mV7 mV10 mVPass
20%12 mV9 mV8 mVPass
30%14 mV11 mV10 mVPass
40%16 mV10 mV12 mVPass
50%15 mV12 mV11 mVPass
60%18 mV11 mV13 mVPass
70%17 mV14 mV15 mVPass
80%20 mV13 mV14 mVPass
90%22 mV15 mV16 mVPass
100%24 mV16 mV18 mVPass
110%27 mV18 mV20 mVPass


As expected given the circuit design and component choices, this is a very good ripple control result, aided by the low resistance cables.

Short Circuit Protection

Short circuit protection is one of the most fundamental and important protections for a power supply. If a short circuit is detected on any rails, the PSU should turn off and prevent damage to itself and other components.

Short Circuit Protection
+12 V railOperational
+5 V railOperational
+3.3 V railOperational

SCP was working as expected with the unit.
Next Page »Value & Conclusion