Kolink Enclave Series 700 W Review 11

Kolink Enclave Series 700 W Review

Cross Load Tests »

Test Setup



Primary Rails Load Regulation

The following charts show the voltage values of the main rails, recorded over a range from 60 W to the maximum specified load, and the deviation (in percent) for the same load range. Tight load regulation is an important characteristic for every power supply since it allows for constant voltage levels despite changes in load.






5VSB Regulation



Hold-up Time

Hold-up time represents the amount of time, usually measured in milliseconds, a PSU can maintain output regulations as defined by the ATX specification without input power. Hold-up time is the amount of time the system can continue to run without shutting down or rebooting during a power interruption. In the following screenshots, the blue line is the mains signal and the green line is the "Power Good" signal, while the yellow line represents the +12V rail.







Inrush Current

Inrush current, or switch-on surge, refers to the maximum instantaneous input current drawn by an electrical device when it is first turned on. Large enough inrush current can cause the tripping of circuit breakers and fuses and may also damage switches, relays, and bridge rectifiers. As a result, the lower the inrush current of a PSU right as it is turned on, the better.


10-110% Load Testing

These tests reveal the KL-G700FM's load regulation and efficiency levels under high ambient temperatures. They also show how the fan-speed profile behaves under tough operating conditions.

Load Regulation & Efficiency Testing Data - Kolink KL-G700FM
Test12 V5 V3.3 V5VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoiseTemp
(In/Out)
PF/AC
Volts
10% Load3.932A1.993A1.941A0.980A69.784W84.540%766 RPM14.3 dB(A)40.10°C0.807
12.253V5.019V3.400V5.105V82.546W42.91°C230.28V
20% Load8.903A2.998A2.923A1.179A139.895W89.923%771 RPM14.7 dB(A)40.73°C0.908
12.241V5.007V3.388V5.089V155.572W44.01°C230.28V
30% Load14.213A3.504A3.405A1.380A209.819W91.662%774 RPM14.8 dB(A)41.23°C0.944
12.229V4.996V3.377V5.075V228.906W45.17°C230.28V
40% Load19.529A4.015A3.921A1.581A279.817W92.324%778 RPM14.9 dB(A)41.82°C0.963
12.218V4.985V3.366V5.060V303.081W46.52°C230.28V
50% Load24.533A5.031A4.921A1.785A349.918W92.515%783 RPM15.0 dB(A)42.03°C0.974
12.204V4.971V3.354V5.044V378.230W47.92°C230.28V
60% Load29.546A6.054A5.924A1.990A420.044W92.401%797 RPM15.5 dB(A)42.54°C0.979
12.192V4.958V3.342V5.028V454.586W49.24°C230.28V
70% Load34.577A7.083A6.939A2.196A490.159W92.024%1458 RPM33.2 dB(A)43.14°C0.983
12.177V4.944V3.328V5.011V532.644W50.46°C230.28V
80% Load39.618A8.119A7.967A2.404A560.272W91.694%1739 RPM39.0 dB(A)43.52°C0.986
12.162V4.930V3.314V4.995V611.023W51.74°C230.28V
90% Load45.062A8.645A8.479A2.408A629.985W91.384%1816 RPM39.7 dB(A)44.19°C0.987
12.149V4.918V3.303V4.985V689.383W52.86°C230.28V
100% Load50.279A9.177A9.028A3.027A700.024W90.936%1830 RPM39.6 dB(A)45.41°C0.987
12.138V4.906V3.291V4.957V769.798W54.38°C230.28V
110% Load56.107A9.197A9.056A3.033A770.034W90.555%1841 RPM39.8 dB(A)46.53°C0.988
12.125V4.896V3.280V4.947V850.345W56.42°C230.27V
Crossload 10.153A12.004A12.000A0.000A102.105W83.900%818 RPM15.9 dB(A)42.00°C0.879
12.233V4.980V3.371V5.110V121.698W47.66°C230.28V
Crossload 258.023A1.003A1.001A1.000A718.389W91.647%1830 RPM39.6 dB(A)45.01°C0.987
12.152V4.934V3.313V5.029V783.861W54.68°C230.28V


Light Load Testing

In the following tests, we measure the KL-G700FM's efficiency at loads significantly lower than 10 percent of its maximum capacity (the lowest load the 80 PLUS standard measures). This is important for when a PC idles with its power-saving features turned on.

Efficiency at Low Loads - Kolink KL-G700FM
Test #12 V5 V3.3 V5 VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoisePF/AC
Volts
12.826A0.499A0.470A0.195A39.752W78.124%758 RPM14.1 dB(A)0.699
12.257V5.032V3.410V5.133V50.883W230.28V
24.065A0.997A0.969A0.390A60.119W83.462%761 RPM14.2 dB(A)0.780
12.254V5.025V3.404V5.124V72.032W230.28V
35.246A1.496A1.440A0.587A79.673W86.352%764 RPM14.2 dB(A)0.828
12.250V5.020V3.400V5.116V92.265W230.28V
46.486A1.997A1.944A0.783A100.045W88.111%766 RPM14.3 dB(A)0.867
12.246V5.016V3.396V5.107V113.544W230.28V


Ultra-Light Load Testing

The applied load in this test is only 10 W for PSUs with 500 W and less capacities, while for stronger units, we dial in 2% of the max-rated-capacity. We only run this test with 115 V input.

Efficiency at Low Loads - Kolink KL-G700FM
Test #12 V5 V3.3 V5 VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoisePF/AC
Volts
11.012A0.209A0.210A0.052A14.448W58.362%753 RPM14.0 dB(A)0.820
12.264V5.037V3.415V5.141V24.756W115.13V

Efficiency

Using the results we gathered so far, we plotted a chart showing the KL-G700FM's efficiency at low loads and loads ranging from 10 to 110 percent of its maximum-rated capacity.


Efficiency with normal loads is high enough, while low with light loads.

5VSB Efficiency

5VSB Efficiency - Kolink KL-G700FM
Test #5VSBPower (DC/AC)EfficiencyPF/AC Volts
10.100A0.515W67.852%0.030
5.140V0.759W230.26V
20.250A1.285W71.948%0.069
5.136V1.786W230.26V
30.550A2.821W75.187%0.136
5.128V3.752W230.26V
41.000A5.116W78.238%0.210
5.115V6.539W230.26V
51.500A7.653W79.183%0.268
5.101V9.665W230.25V
63.001A15.180W80.013%0.360
5.059V18.972W230.26V

The 5VSB rail is efficient.

Power Consumption in Idle and Standby

Idle / Standby - Kolink KL-G700FM
Mode12 V5 V3.3 V5VSBPower (AC)PF/AC Volts
Idle12.253V5.038V3.413V5.143V11.055W0.302
230.3V
Standby0.139W0.005
230.3V

Fan RPM, Delta Temperature and Output Noise

The following results were obtained at 37–47 °C ambient.





The following results were obtained at 30–32 °C ambient.



Next Page »Cross Load Tests
View as single page