MOAIPLAY ORA PRO G1 1000 Review 3

MOAIPLAY ORA PRO G1 1000 Review

Value & Conclusion »

Result Summary

Full-Range Load Testing (230 V)
All-rail
Load
12 V5 V3.3 VPower
(DC/AC)
EfficiencyFan
Speed
Noise
Level
Power
Factor
0 %0.00 A0.0 A0.0 A0.00 WN/AFan Stop0.11
12.21 V5.12 V3.34 V4.70 W
5 %3.82 A0.5 A0.5 A50.00 W85.62 %Fan Stop0.59
12.13 V5.12 V3.34 V58.40 W
10 %7.64 A1.0 A1.0 A100.00 W89.45 %Fan Stop0.76
12.12 V5.12 V3.34 V111.80 W
20 %15.28 A2.0 A2.0 A200.00 W92.29 %Fan Stop0.89
12.11 V5.11 V3.33 V216.70 W
30 %22.93 A3.0 A3.0 A300.00 W92.45 %Fan Stop0.93
12.11 V5.11 V3.33 V324.50 W
40 %30.57 A4.0 A4.0 A400.00 W92.70 %Fan Stop0.95
12.11 V5.11 V3.33 V431.50 W
50 %38.21 A5.0 A5.0 A500.00 W92.85 %Fan Stop0.96
12.10 V5.10 V3.32 V538.50 W
60 %45.85 A6.0 A6.0 A600.00 W92.58 %Fan Stop0.96
12.09 V5.10 V3.32 V648.10 W
70 %53.49 A7.0 A7.0 A700.00 W92.21 %Fan Stop0.97
12.08 V5.09 V3.31 V759.10 W
80 %61.13 A8.0 A8.0 A800.00 W91.36 %Fan Stop0.98
12.08 V5.09 V3.31 V875.70 W
90 %68.78 A9.0 A9.0 A900.00 W90.80 %Fan Stop0.98
12.07 V5.09 V3.31 V991.20 W
100 %76.42 A10.0 A10.0 A1000.00 W90.50 %645.2 RPM26.2 dBA0.98
12.07 V5.08 V3.30 V1105.00 W
110 %84.06 A11.0 A11.0 A1100.00 W90.09 %689.0 RPM26.3 dBA0.98
12.06 V5.08 V3.30 V1221.00 W

Efficiency





Rated Efficiency Validation (230 V)
Certification: Uncertified (meets 80 Plus Gold)
Test LoadRequiredMeasuredMarginStatus
20%90.00 %92.29 %+2.29 %Pass
50%92.00 %92.85 %+0.85 %Pass
100%89.00 %90.50 %+1.50 %Pass

If this PSU was certified by the 80 Plus scheme, it would fall comfortably into 80 Plus Gold, achieving over 92% at 20% and 50% load, and over 89% at 100% load. The efficiency comes in a touch better than the FSP 1000 W model we have tested, but just behind the Formula V Line using the same PCB, likely due to the higher RDS(on) MOSFETs in this model losing more energy as heat.

Fan Noise


It is worth noting that just like with the Formula V Line, we discovered that this switch is operating backwards to how it suggests. With the switch in the ON position, the fan runs constantly at a low speed, and increases with load intensity. With the switch in OFF position, the fan completely turns off until we exceed a temperature threshold. So if you want semi-passive operation, the switch must be in the OFF position. This will catch a lot of people out, who will rightly assume the switch position relates to the activation status of the Zero Fan. The switch has not been connected backwards, as it is a standard single-throw switch (ON/OFF as opposed to ON/ON).

Another observation is that the fan remained off throughout the majority of the test, and only came on at a 90% load. This is wildly different to what we saw with the Formula V Line, which is very strange as it is the same board. During testing up to 80%, the PSU was getting noticeably hot, with temperatures on the transformer output plate reaching over 70 C. The test was repeated a number of times to confirm this wasn't an isolated event, and the same results occurred. It would seem that the thermistor calibration may either be off on this unit, or varies significantly between models. The fan also never really got up to a high speed, even with the supply sitting on a 110% load for a long time, the fan remained around 650 RPM and virtually silent.

As expected, this model achieves the lowest noise result we have seen so far, thanks to its huge fan and very late activation, whether intentional or not.

Voltage Regulation

As with almost all modern PSUs, the internal feedback loop regulating the output voltage at the supply itself is extremely effective, only dropping by a tiny fraction as the load increases. Interestingly, this is in stark contrast to what was seen with the Formula V Line supply, which although shared the same PCB, suffered with significant voltage drop at the supply outputs themselves.

Voltage Regulation
Test Load+12 V+5 V+3.3 VStatus
Idle12.21 V5.12 V3.34 VPass
25% load12.11 V5.11 V3.33 VPass
50% load12.10 V5.10 V3.32 VPass
75% load12.08 V5.09 V3.31 VPass
100% load12.07 V5.08 V3.30 VPass

Cable Quality

Although voltage regulation inside modern PSUs is (usually) extremely stable, voltage drop and thus power losses will occur across the cables as current is drawn through them. This results in a lower voltage available to the system components than what is actually measured at the PSU outputs. Thicker cables will cause less voltage drop and more power to the components. Any power lost across the cables is wasted as heat in the wire itself. By measuring the voltage drop at a known load, we can calculate the resistance of the individual cables.

Cable Losses at Full Load
Applied 12 V Load76.43 A
Measured @ Supply12.07 V
Measured @ Load11.70 V
Power Lost in Cable28.28 W
Per-Cable Resistance106.50 mΩ




While the resistance of these cables is on the higher end of the supplies we have tested recently, the power lost at 100% load is acceptable, and the voltage dropped within ATX spec.

Ripple

Ideally you want the DC voltage delivered by your power supply to be a completely flat line when looking through an oscilloscope. However, due to the switching nature of the ATX power supply and the less than ideal real world behavior of all the components involved, we get very small fluctuations in the voltage output, known as ripple and noise. The ATX spec allows a ripple of up to 120 mV for the +12 V rail and 50 mV for the minor rails (measured in mV P-P).

Ripple (mV P-P) - 230 V
Test Load12 V5 V3.3 VStatus
10%28.92 mV18.65 mV18.30 mVPass
20%31.24 mV18.52 mV17.88 mVPass
30%30.55 mV20.12 mV19.45 mVPass
40%30.85 mV21.10 mV19.72 mVPass
50%31.15 mV21.22 mV19.85 mVPass
60%31.50 mV20.85 mV20.25 mVPass
70%31.95 mV22.45 mV20.88 mVPass
80%33.12 mV23.35 mV24.12 mVPass
90%32.65 mV24.25 mV24.65 mVPass
100%33.25 mV23.85 mV24.85 mVPass
110%34.15 mV24.95 mV25.55 mVPass


The ripple across all rails is controlled and well within ATX specification. The results are naturally very similar to the Formula V Line, but a little better across the board likely thanks to the higher quality capacitors used.

Short Circuit Protection

Short circuit protection is one of the most fundamental and important protections for a power supply. If a short circuit is detected on any rails, the PSU should turn off and prevent damage to itself and other components.

Short Circuit Protection
+12 V railOperational
+5 V railOperational
+3.3 V railOperational

SCP was working as expected with the unit.
Next Page »Value & Conclusion