NZXT C1200 Platinum Review 3

NZXT C1200 Platinum Review

Value & Conclusion »

Result Summary

Full-Range Load Testing (230 V)
All-rail
Load
12 V5 V3.3 VPower
(DC/AC)
EfficiencyFan
Speed
Noise
Level
Power
Factor
0 %0 A0.00 A0.00 A0.00 W0.00 %Fan Stop0.06
11.86 V5.03 V3.29 V3.00 W
5 %1.67 A4.00 A6.06 A60.00 W83.33 %Fan Stop0.72
11.91 V5.06 V3.32 V72.00 W
10 %6.67 A4.00 A6.06 A120.00 W86.89 %Fan Stop0.85
12.00 V5.06 V3.32 V138.10 W
20 %16.67 A4.00 A6.06 A240.00 W91.74 %Fan Stop0.91
11.98 V5.06 V3.32 V261.60 W
30 %26.67 A4.00 A6.06 A360.00 W92.49 %Fan Stop0.94
11.96 V5.06 V3.32 V389.25 W
40 %36.67 A4.00 A6.06 A480.00 W93.08 %Fan Stop0.95
11.95 V5.06 V3.32 V515.70 W
50 %46.67 A4.00 A6.06 A600.00 W93.25 %377 RPM26.4 dBA0.96
11.93 V5.06 V3.32 V643.40 W
60 %56.67 A4.00 A6.06 A720.00 W93.16 %462 RPM26.5 dBA0.96
11.92 V5.06 V3.32 V772.90 W
70 %66.67 A4.00 A6.06 A840.00 W93.06 %608 RPM26.9 dBA0.97
11.91 V5.06 V3.32 V902.65 W
80 %76.67 A4.00 A6.06 A960.00 W92.75 %720 RPM27.2 dBA0.97
11.89 V5.06 V3.32 V1035.00 W
90 %86.67 A4.00 A6.06 A1080.00 W92.47 %857 RPM28.0 dBA0.97
11.88 V5.06 V3.32 V1168.00 W
100 %96.67 A4.00 A6.06 A1200.00 W91.60 %1020 RPM32.3 dBA0.98
11.86 V5.06 V3.32 V1310.00 W
110 %106.67 A4.00 A6.06 A1320.00 W91.22 %1242 RPM39.1 dBA0.98
11.85 V5.06 V3.32 V1447.00 W

Efficiency




This supply is rated as 80 Plus Platinum; however, this is based on the 115 V measurements. NZXT do not provide an 80 Plus rating at 230 V, so we will compare the measurements to the 80 Plus Platinum (230 V) standard.

Rated Efficiency Validation (230 V)
Certification: 80 Plus Platinum
Test LoadRequiredMeasuredMarginStatus
20%92.00 %91.74 %-0.26 %Borderline
50%94.00 %93.25 %-0.75 %Borderline
100%90.00 %91.60 %+1.60 %Pass

On our test setup, this model pretty much matches the threshold for a Platinum badge at 230 V, coming up a little short at 20 % and 50 %, which can be a combination of 115 V efficiency optimizations and also testing method variance since we hold 3.3 V and 5 V at a fixed power level. Overall, this is a great result on our bench at 230 V.

The marketing for this supply claims a power factor of 0.99, however at 230 V it doesn't manage to reach this mark even at high loads.

Fan Noise


Although this is using the same base fan model as the Corsair RM1200e (2nd gen), there are some differences. Firstly, the programmed curve is less intense, meaning the fan remains slower and quieter throughout the entire power band; however, the 3D grille on the Corsair does seem to help a little, as at similar speeds the NZXT is a little louder. Overall though, this PSU remained very quiet even pushed to very high loads, due to spinning slower at a given load.

Voltage Regulation

All ATX PSUs have a voltage regulation feedback loop, which increases the PWM duty cycle for each rail to account for voltage drop when current is drawn. However, most PSUs only measure voltage at the PSU output, rather than at the end of the cable going to the load. This means any voltage drop across the cable is not automatically adjusted for. The ATX 3.1 specification outlines a maximum allowed voltage drop at the load itself to ensure system stability.

Voltage Regulation & ATX 3.1 Compliance
Test LoadRailMeasuredATX 3.1 Spec LimitMarginStatus
Idle (0%)+12V11.86 V+5 %/-8 %-1.17 %Pass
+5V5.03 V±5 %+0.60 %Pass
+3.3V3.29 V±5 %-0.30 %Pass
100% Load+12V11.86 V+5 %/-8 %-1.17 %Pass
+5V5.06 V±5 %+1.20 %Pass
+3.3V3.32 V±5 %+0.61 %Pass


When completely idle, the PWM switching mode seems to cause the voltage on the 12 V rail to sit a bit under target. However, as soon as a load is applied the voltage increases, and by 10% it is up at exactly 12 V. As the load increases to full rated current, the sag across the cables drops it back down by a little over 1%, which is well within ATX tolerances. The minor rails are not affected by the variance on the 12 V rail.

Cable Quality

Although voltage regulation inside modern PSUs is extremely stable, voltage drop and thus power losses will occur across the cables as current is drawn through them. This results in a lower voltage available to the system components than what is actually measured at the PSU outputs. Thicker cables will cause less voltage drop and more power to the components. Any power lost across the cables is wasted as heat in the wire itself. By measuring the voltage drop at a known load, we can calculate the resistance of the cables.

Cable Losses at Full Load
Applied 12 V Load106.67 A
Measured @ Supply11.99 V
Measured @ Load11.85 V
Power Lost in Cable14.93 W
Per-Cable Resistance65.62 mΩ
Cable Temperature25.5 °C


This is a decent result, with even current sharing across multiple parallel cables, overall low cable and connector resistance at this price point, and minimal power lost during high power draw. The result is nearly identical to the Corsair RM1200e and I suspect they are the exact same cables given the packaging and component similarities.


Testing the 12V-2x6 cable alone under a 600 W load, we calculate the individual wire resistance a touch lower at 48.0 mΩ, which is an excellent low result, again almost identical to the 50 mΩ we saw on the Corsair.



Ripple

Ideally you want the DC voltage delivered by your power supply to be a completely flat line when looking through an oscilloscope. However, due to the switching nature of the ATX power supply and the less than ideal real world behavior of all the components involved, we get very small fluctuations in the voltage output, known as ripple and noise. The ATX spec allows a ripple of up to 120 mV for the +12 V rail and 50 mV for the minor rails.

Ripple (mV)
Test Load12 V5 V3.3 VStatus
5%16 mV14 mV15 mVPass
10%15 mV16 mV14 mVPass
20%18 mV15 mV18 mVPass
30%17 mV19 mV17 mVPass
40%21 mV18 mV21 mVPass
50%24 mV22 mV23 mVPass
60%23 mV21 mV22 mVPass
70%27 mV25 mV26 mVPass
80%29 mV24 mV29 mVPass
90%28 mV27 mV28 mVPass
100%34 mV29 mV32 mVPass
110%38 mV32 mV36 mVPass


This is a perfectly fair ripple control result with good measurements across the board; the PWM mode shift is visible here also in the 5 % and 10 % readings on the 12 V rail.

Short Circuit Protection

Short circuit protection is one of the most fundamental and important protections for a power supply. If a short circuit is detected on any rails, the PSU should turn off and prevent damage to itself and other components.

Short Circuit Protection
+12 V railOperational
+5 V railOperational
+3.3 V railOperational

SCP worked as expected with the unit.