Rapoo VT7 Max Review 10

Rapoo VT7 Max Review

Testing 8000 Hz Wired & Wireless »

Sensor and Performance

The Rapoo VT7 Max is equipped with the PixArt PAW3950 Ultimate. According to specifications, the 3950 is capable of up to 45,000 CPI, as well as a maximum tracking speed of 750 IPS, which equals 19.05 m/s. Out of the box, seven pre-defined CPI steps are available: 400, 800, 1200, 1600, 3200, 6400, and 30,000.

All testing was done on the latest firmware (0.63/0.22-0.50). As such, results obtained on earlier firmware versions may differ from those presented hereafter.

Notice: For testing on more recent firmware, please refer to the review of the VT2 Max.

Issue: Mouse Disconnects in Wired Mode


A severe issue emerges in wired operation only. Regardless of setting, moving the mouse at moderate (1+ m/s) velocity will result in frequent disconnects for roughly 400 ms or a multiple of it. These still occur when using different cables or USB ports and therefore can be assumed to be entirely device related.

CPI Accuracy

What is CPI Accuracy?
"CPI" (short for counts per inch) describes the number of counts registered by the mouse if it is moved exactly an inch. There are several factors (firmware, mounting height of the sensor not meeting specifications, mouse feet thickness, mousing surface, among others) which may contribute to nominal CPI not matching actual CPI. It is impossible to always achieve a perfect match, but ideally, nominal and actual CPI should differ as little as possible. In this test, I'm determining whether this is the case or not. However, please keep in mind that said variance will still differ from unit to unit, so your mileage may vary.


I've restricted my testing to the four most common CPI steps, which are 400, 800, 1600, and 3200. As you can see, deviation is consistently positive and very low, which is an excellent result overall. In order to account for the measured deviation, adjusted steps of 400, 790, 1580, and 3160 CPI have been used for testing.

Motion Delay

What is Motion Delay?
"Motion delay" encompasses all kinds of sensor lag. Any further sources of input delay will not be recorded in this test. The main thing I'll be looking for in this test is sensor smoothing, which describes an averaging of motion data across several capture frames, in order to reduce jitter at higher CPI values, increasing motion delay along with it. The goal here is to have as little smoothing as possible. As there is no way to accurately measure motion delay absolutely without special equipment, it is done by comparison with a control subject that has been determined to have consistent and low motion delay. In this case, the control subject is a Logitech G403, whose PMW3366 sensor has no visible smoothing across the entire CPI range. Note that the G403 is moved first and thus receives a slight head start.

Wired testing

First, I'm looking at two xCounts plots—generated at 1600 and 45,000 CPI—to quickly gauge whether there is any smoothing, which would be indicated by any visible "kinks." Neither plot shows any kinks, strongly suggesting there not being any smoothing across the entire CPI range.


The VT7 Max also allows enabling MotionSync, which effectively synchronizes SPI reads with USB polls, resulting in very low SPI timing jitter as seen above.


Even in wired mode, the VT7 Max allows selecting from a wide range of possible sensor run modes. Given that power draw is not a concern, opting for one of the three corded modes is reasonable: "Hyper Core," "Gaming Hyper Core," (first plot) and "Fury Gaming" (second plot). While the first two show no difference in tracking, the third one, which sets sensor framerate to up to 20,000, does.



In order to determine motion delay, I'm looking at xSum plots generated at 1600 and 45,000 CPI, both without (first row) and with (second row) MotionSync. The line further to the left denotes the sensor with less motion delay. Without MotionSync, a motion delay differential of 1 ms in favor of the VT7 Max can be measured at 1600 CPI, whereas the VT7 Max is behind by 2 ms at 45,000 CPI, despite ripple control not being enabled. With MotionSync, a motion delay differential of close to 1 ms is added.

Wireless testing


Much like in wired mode, one may select from a wide range of available sensor run modes, and unlike in wired mode, doing so has merit given the significant differences in power draw between them. Both LP (first row, first plot) and HP (first row, second plot) show higher SPI timing jitter, whereas the variants of corded mode called "Hyper Core" (second row, first plot) and "Fury Gaming" (second row, second plot) present a lower level of SPI timing jitter.



Upon enabling MotionSync, SPI timing is tightened to a similar degree across all sensor run modes.



1600 CPI both without (first row) and with (second row) MotionSync is tested. Without MotionSync, the VT7 Max is ahead by 0.4 ms in HP mode (first plot) and by 0.9 ms in corded mode (second plot). With MotionSync, a motion delay differential of close to 1 ms is added once again.

What is Speed-related Accuracy Variance?
What people typically mean when they talk about "acceleration" is speed-related accuracy variance (or SRAV). It's not about the mouse having a set amount of inherent positive or negative acceleration, but about the cursor not traveling the same distance if the mouse is moved the same physical distance at different speeds. The easiest way to test this is by comparison with a control subject that is known to have very low SRAV, which in this case is the G403.


As you can see from the plot, no displacement between the two cursor paths can be observed, which confirms that SRAV is very low.

Perfect Control Speed

What is Perfect Control Speed?
Perfect Control Speed (or PCS for short) is the maximum speed up to which the mouse and its sensor can be moved without the sensor malfunctioning in any way.


I've only managed to hit a measly 5 m/s, which is within the proclaimed PCS range and causes no observable sensor malfunction.

Polling Rate Stability

What is Polling Rate?
Strictly speaking, one has to distinguish between polling rate and report rate. Polling rate describes the number of times the host (typically the user's PC) polls the device, whereas report rate describes the number of times the device reports to the host. Thus, a device can be set to be polled a certain number of times per second, but report at a lower rate regardless, either by design (i.e., if there have been no movement changes since the previous report) or not by design, and the latter case is what will be tested under the moniker of "polling rate stability" hereafter. To this end, the mouse is set to a sufficiently high CPI step and moved at a sufficiently high velocity to ensure that the maximum possible report rate is achieved at all times. Polling rate can be conceived of as a frequency, which is typically measured in Hz, though a more apt way of looking at it would be as an interval. For reference, a frequency of 1000 Hz is tantamount to an interval of 1 ms. Likewise, a frequency of 125 Hz would translate to an interval of 8 ms, and a frequency of 8000 Hz to an interval of 0.125 ms.

Wired testing


All the available polling rates (125, 250, 500, or 1000 Hz) display instances of noise.

Wireless testing
For wired mice, polling rate stability merely concerns the wired connection between the mouse (SPI communication) and USB. For wireless mice, another device that needs to be kept in sync between the first two is added to the mix: the wireless dongle/wireless receiver. I'm unable to measure all stages of the entire end-to-end signal chain individually, so testing polling-rate stability at the endpoint (the USB) has to suffice here.


First, I'm testing whether SPI, wireless, and USB communication are synchronized. Any of these being out of sync would be indicated by at least one 2 ms report, which would be the result of any desynchronization drift accumulated over time. There are no periodic off-period polls indicative of a desynchronization drift, but instances of noise are present throughout.



Second, I'm testing the general polling-rate stability of the individual polling rates in wireless mode. Running the VT7 Max at a lower polling rate can have the benefit of extending battery life. All polling rates display instances of noise.


Occasionally, polling will break completely, for reasons unknown.

Paint Test

What is the Paint Test?
This test is used to indicate any potential issues with angle snapping (non-native straightening of linear motion) and jitter, along with any sensor lens rattle.


As you can see, no issues with angle snapping can be observed. There is no jitter visible at 1600 CPI. 45,000 CPI shows major jitter, which is only marginally lessened by enabling ripple control (third row). As an aside, controlling the cursor at 45,000 is almost impossible. Lastly, there is no lens movement.

Lift-off Distance

What is Lift-off Distance?
Lift-off distance describes the distance the mouse can be lifted off the tracking surface until the sensor no longer tracks.

The VT7 Max offers eleven pre-defined LOD levels. Between the "0.7" and "1.3" settings, the sensor does not track at a height of one DVD (<1.2 mm). At and above the "1.4" setting, the sensor does track at a height of one DVD (1.2 mm<x<2.4 mm, with x being LOD height), but not at a height of two DVDs. Keep in mind that LOD may vary slightly depending on the mousing surface (pad) it is being used on.

Click Latency

What is Click Latency?
In most computer mice, debouncing is required to avoid double clicks, slam-clicks, or other unintended effects of switch bouncing. Debouncing typically adds a delay, which, along with any potential processing delay, shall be referred to as click latency. In order to measure click latency, the mouse has been interfaced with an NVIDIA LDAT (Latency Display Analysis Tool). Many thanks go to NVIDIA for providing an LDAT device. More specifically, the LDAT measures the time between the electrical activation of the left main button and the OS receiving the button-down message. Unless noted otherwise, the values presented in the graph refer to the lowest click latency possible on the mouse in question. If a comparison mouse is capable of both wired and wireless operation, only the result for wireless (2.4 GHz) operation will be listed. All the listed values have been gathered without any sensor motion. If latency differs between no motion and motion, it will be noted as such.


In wired mode, and using a debounce time of 1 ms, click latency has been measured to be 3.8 ms, with standard deviation being 0.31 ms.

In wireless mode, at 1000 Hz, and using a debounce time of 1 ms, click latency has been measured to be 4.5 ms, with standard deviation being 0.42 ms. In wireless mode, at 2000 Hz, and using a debounce time of 1 ms, click latency has been measured to be 4.2 ms, with standard deviation being 0.38 ms. In wireless mode, at 4000 Hz, and using a debounce time of 1 ms, click latency has been measured to be 4.0 ms, with standard deviation being 0.37 ms. Finally, in wireless mode, at 8000 Hz, and using a debounce time of 1 ms, click latency has been measured to be 3.9 ms, with standard deviation being 0.27 ms.