Seasonic Vertex GX 850 W Review 10

Seasonic Vertex GX 850 W Review

Value & Conclusion »

Result Summary

Test results (AC @ 230 V) - Seasonic Vertex GX 850 W
Test12 V5 V3.3 VPower
(DC/AC)
EfficiencyFan spinning?Noise levelTemp
(In/Out)

Power Factor

5 %2.84 A1.02 A1.03 A43.28 W82.35 %No26.8 dBA39.0 °C0.72
12.21 V5.060 V3.345 V52.56 W37.5 °C
10 %5.83 A1.70 A1.74 A85.49 W86.03 %No26.8 dBA40.7°C0.85
12.20 V5.050 V3.330 V99.37 W37.7 °C
20 %12.30 A2.56 A2.60 A171.48 W90.81 %No26.8 dBA40.4 °C

0.93

12.19 V5.040 V3.322 V188.82 W38.8 °C
30 %19.06 A3.00 A2.97 A256.90 W92.50 %No26.8 dBA42.1 °C0.96
12.17 V5.032 V3.315 V277.73 W39.7 °C
40 %25.91 A3.50 A3.43 A343.96 W92.54 %722 RPM28.4 dBA40.6 °C0.97
12.16 V5.021 V3.303 V371.71 W40.5 °C
50 %32.44 A4.38 A4.30 A430.21 W92.34 %722 RPM28.4 dBA42.3 °C0.98
12.15 V5.005 V3.290 V465.91 W43.8 °C
60 %38.90 A5.30 A5.19 A515.68 W91.72 %805 RPM29.3 dBA41.8 °C0.99
12.14 V4.985 V3.278 V562.26 W43.3 °C
70 %45.46 A6.20 A6.07 A601.17 W91.05 %842 RPM29.5 dBA40.7 °C0.99
12.11 V4.973 V3.264 V660.23 W43.4 °C
80 %52.55 A6.40 A6.33 A687.70 W90.42 %930 RPM30.2 dBA41.5 °C0.99
12.09 V4.963 V3.256 V760.53 W43.7 °C
90 %59.20 A7.22 A7.15 A773.47 W89.73 %1012 RPM32.1 dBA42.3 °C0.99
12.07 V4.948 V3.245 V862.03 W43.8 °C
100 %66.12 A8.04 A7.43 A859.86 W89.04 %1056 RPM32.4 dBA44.2 °C0.99
12.04 V4.937 V3.241 V965.70 W46.4 °C
110 %73.03 A8.91 A8.21 A947.45 W88.28 %1390 RPM36.7 dBA43.3 °C0.99
12.01 V4.923 V3.227 V1073.28 W47.3 °C

Just as expected the Vertex GX 850 W passed our tests from 5 % all the way to 110 % of its rated power, without any issues. The main observations from the results table above is as always about the acoustics. The fan started ramping up slowly when we reached 40 % of the load and then had a very mild climb, experiencing a slightly steeper rise only at the very end of the tests. Most importantly throughout the testing even at high loads the unit was barely audible, confirming the initial expectations.

While the unit's efficiency easily matched the 80 Plus Gold standard (more on that in the following paragraph), the power factor correction results were not that great at very low loads. While this is by no means a significant downside (and a better result than then Focus GX showed), a 0.72 PF at 5 % load and 0.85 PF at 10 % is not an impressive result.



The efficiency of the unit was also not the greatest during the first two tests, but quickly caught up and reached 90.81 % at 20 % load. The efficiency stayed high overall with the highest value reaching 92.54 %. The efficiency at 20, 50 and 100 % of its rated capacity easily match the 230 V requirements for an 80 Plus Gold rating, especially knowing that the tests were done at or above 40 °C ambient temperature. The efficiency dropoff after the peak is also very linear, without a commonly observed significant dropoff at the overload test.

Voltage Regulation

Voltage regulation - Seasonic Vertex GX 850 W
Test+12 V+5 V+3.3 V
5 %1.75 %1.20 %1.36 %
10 %1.67 %1.00 %0.91 %
20 %1.58 %0.80 %0.67 %
30 %1.42 %0.64 %0.45 %
40 %1.33 %0.40 %0.09 %
50 %1.25 %0.10 %-0.30 %
60 %1.17 %-0.30 %-0.67 %
70 %0.92 %-0.54 %-1.09 %
80 %0.75 %-0.74 %-1.33 %
90 %0.58 %-1.04 %-1.67 %
100%0.33 %-1.26 %-1.79 %
110 %0.08 %-1.54 %-2.21 %







The regulation for the +12 V rail of the Vertex GX is great. Handling of the minor rails is very good. While we have definitely seen better results for the +3.3 V rail, 1.79 % at 100 % load is an overall above average result in the group of very capable PSUs we have been testing for the past year.

Ripple

Ideally you want the DC voltage delivered by your power supply to be a completely flat line when looking through an oscilloscope. However, due to the switching nature of the ATX power supply and the less than ideal real world behavior of all the components involved, we get very small fluctuations in the voltage that are known as ripple and noise. The ATX spec allows a ripple of up to 120 mV for the +12 V rail and 50 mV for the minor rails.

Ripple - Seasonic Vertex GX 850 W
Test12 V5 V3.3 V
5 %14 mV12 mV12 mV
10 %14 mV16 mV12 mV
20 %16 mV12 mV14 mV
30 %16 mV14 mV16 mV
40 %18 mV16 mV18 mV
50 %24 mV20 mV14 mV
60 %26 mV20 mV16 mV
70 %28 mV20 mV16 mV
80 %30 mV24 mV18 mV
90 %32 mV24 mV20 mV
100%34 mV26 mV22 mV
110 %36 mV30 mV24 mV

Ripple control for the Vertex GX 850 W is good, but not great. Of course, it easily fits within the defined ATX specs. An oscillogram from the 110 % load test can be seen below.



Short Circuit Protection

Short circuit protection is one of the most fundamental and important protections for a power supply. If a short circuit is detected on any rails, the PSU should turn off and prevent damage to itself and other components.

Short Circuit Protection
+12 V railOperational
+5 V railOperational
+3.3 V railOperational

SCP was working as expected with the unit.