Sensor and Performance

The VAXEE NP-01 is equipped with the PixArt PMW3389. According to specifications, the 3389 is capable of up to 16,000 CPI, as well as a maximum tracking speed of 400 IPS, which equals 10.16 m/s. Out of the box, four pre-defined CPI steps are available: 400, 800, 1600, and 3200 CPI.

CPI Accuracy

"CPI" (short for counts per inch) describes the amount of counts registered by the mouse if it is moved exactly an inch. There are several factors (firmware, mounting height of the sensor not meeting specifications, mouse feet thickness, mousing surface, among others) which may contribute to nominal CPI not matching actual CPI. It is impossible to always achieve a perfect match, but ideally, nominal and actual CPI should differ as little as possible. In this test, I'm determining whether this is the case or not. However, please keep in mind that said variance will still vary from unit to unit, so your mileage may vary.


I've restricted my testing to the four most common CPI steps, which are 400, 800, 1600, and 3200. The NP-01 lacks the ability to freely adjust CPI steps, which is why CPI accuracy is particularly important. As you can see, deviation is rather high and exclusively positive. A below average result overall.

Motion Delay

"Motion delay" encompasses all kinds of sensor lag. Any further sources of input delay will not be recorded in this test. The main thing I'll be looking for in this test is sensor smoothing, which describes an averaging of motion data across several capture frames in order to reduce jitter at higher CPI values, increasing motion delay along with it. The goal here is to have as little smoothing as possible. As there is no way to accurately measure motion delay absolutely, it can only be done by comparison with a control subject that has been determined to have the lowest possible motion delay. In this case the control subject is a G403, whose 3366 has no visible smoothing across the entire CPI range. Note that the G403 is moved first and thus receives a slight head start.


First, I'm looking at two xCounts plots—generated at 1600 and 3200 CPI—to quickly gauge whether there is any smoothing, which would be indicated by any visible "kinks." Typically, the 3200 CPI plot would show such "kinks" given the 3389 usually has 32 frames of smoothing at and above 1900 CPI, which amounts to an added motion delay of roughly 4 ms at the lowest possible speed. As you can see, this is the case here, although the kinks are just barely visible. What we can also see is very clean tracking without any SPI timing jitter worth noting.


In order to determine motion delay, I'm looking at xSum plots generated at 1600 and 3200 CPI. The line further to the left denotes the sensor with less motion delay. At 1600 CPI, there is no difference in motion delay. At 3200 CPI, a motion delay differential of roughly 3.5 ms can be seen. This is in line with what to expect from a 3389, which has 32 frames of smoothing at and above 1900 CPI.


What people typically mean when they talk about "acceleration" is speed-related accuracy variance (or short SRAV). It's not about the mouse having a set amount of inherent positive or negative acceleration, but about the cursor not traveling the same distance if the mouse is moved the same physical distance at different speeds. The easiest way to test this is by comparison with a control subject that is known to have very low SRAV, which in this case is the G403. As you can see from the plot, no displacement between the two cursor paths can be observed, which confirms that SRAV is very low.

Perfect Control Speed


Perfect Control Speed (or PCS for short) is the maximum speed up to which the mouse and its sensor can be moved without the sensor malfunctioning in any way. I've only managed to hit a measly 4.5 m/s (which is within the proclaimed PCS range), at which no sign of the sensor malfunctioning can be observed.

Polling Rate Stability


All three available polling rates (125 Hz, 500 Hz, and 1000 Hz) look nice and stable.

Paint Test


This test is used to indicate any potential issues with angle snapping (non-native straightening of linear motion) and jitter, along with any sensor lens rattle. As you can see, no issues with angle snapping can be observed. No jitter is visible at any of the tested CPI steps. Lastly, there is no sensor lens movement at the tested step of 3200 CPI, which is the highest step available on the NP-01.

Lift-off Distance

The NP-01 offers three pre-defined LOD levels to choose from. For instructions on how to swap between them, please refer to this. At the default "Low" setting, the sensor just barely (only intermittently) tracks at a height of 1 DVD (<1.2 mm). At the "Medium" setting, the sensor does track at a height of 1 DVD, but not at a height of 2 DVDs (1.2<x<2.4 mm; x=LOD height). At the "High" setting, the sensor still does not track at a height of 2 DVDs. Keep in mind that LOD may vary slightly depending on the mousing surface (pad) it is being used on.

Click Latency


Since mechanical switches are being used for the buttons in most computer mice, debouncing is required in order to avoid unintended double clicks. Debouncing typically adds a delay (along with any potential processing delay), which shall be referred to as click latency. As there is no way to measure said delay directly, it has to be done by comparing it to a control subject, which in this case is the Logitech G100s. Interestingly, the on-device button response time adjustment doesn't behave entirely deterministically. The 4 ms and 8 ms settings are separated by exactly 4 ms, which is expected, clocking in at +3.8 ms and +7.8 ms (respectively) relative to the SteelSeries Ikari, which is considered as the baseline with 0 ms. The 2 ms setting, however, consistently came out at +1.2 ms, which is 0.6 ms less than expected. Please keep in mind that the measured value is not the absolute click latency. Comparison data comes from this thread as well as my own testing, using qsxcv's program.