Cooler Master V750 Semi-Modular 750 W Review 7

Cooler Master V750 Semi-Modular 750 W Review

Performance Rating, Performance per Dollar, Noise & Efficiency Rating »

Ripple Measurements

You will see the ripple levels we measured on the VSM750's rails in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements - Cooler Master VSM750
Test12 V5 V3.3 V5VSBPass/Fail
10% Load6.5 mV5.6 mV10.8 mV5.4 mVPass
20% Load8.2 mV6.7 mV11.4 mV6.0 mVPass
30% Load17.1 mV7.7 mV11.4 mV6.8 mVPass
40% Load17.4 mV9.4 mV12.6 mV7.4 mVPass
50% Load19.6 mV10.4 mV12.0 mV7.7 mVPass
60% Load21.4 mV11.3 mV13.7 mV8.1 mVPass
70% Load23.5 mV12.2 mV13.3 mV8.6 mVPass
80% Load25.1 mV12.9 mV13.9 mV9.0 mVPass
90% Load26.7 mV13.8 mV14.2 mV9.5 mVPass
100% Load29.3 mV15.7 mV15.9 mV10.1 mVPass
110% Load31.9 mV16.5 mV16.3 mV10.9 mVPass
Crossload 115.1 mV7.5 mV12.6 mV6.7 mVPass
Crossload 228.9 mV14.9 mV14.1 mV9.2 mVPass

Ripple suppression was great on all rails. The unit's good design and its Japanese caps obviously did a fine job here. The good thing about Japanese caps is that they don't only perform incredibly well, but also keep their high performance for much longer than Chinese caps. In other words, they age much slower, which allows the PSU to retain most of its initial performance as time goes on.

Ripple at Full Load

You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2

Next Page »Performance Rating, Performance per Dollar, Noise & Efficiency Rating
View as single page
Apr 26th, 2024 11:57 EDT change timezone

New Forum Posts

Popular Reviews

Controversial News Posts