1st Player Steampunk PS-850SP 850 W Review 10

1st Player Steampunk PS-850SP 850 W Review

Efficiency »

Test Setup



Primary Rails Load Regulation

The following charts show the voltage values of the main rails, recorded over a range from 60 W to the maximum specified load, and the deviation (in percent) for the same load range. Tight load regulation is essential for every power supply because it allows for constant voltage levels despite changes in load.







5VSB Regulation



Load regulation is within 1% at +12 V and 5 V, which is quite good. On other other hand, it is loose on the 3.3 V and 5VSB rails.

Ripple Measurements

Ripple represents the AC fluctuations (periodic) and noise (random) found in the DC rails of PSUs. Ripple significantly decreases the life span of capacitors because it increases their temperature; a 10 °C increase can cut into a capacitor's life span by up to 50 percent. Ripple also plays a vital role in overall system stability, especially when it is overclocked. According to the ATX specification, the ripple limits are 120 mV (+12V) and 50 mV (+5V, +3.3V, and 5VSB).

Ripple Measurements - 1st Player Steampunk Gold 850W
Test12V5V3.3V5VSBPass/Fail
10% Load32.3 mV11.5 mV19.0 mV4.0 mVPass
20% Load19.1 mV10.4 mV19.6 mV4.5 mVPass
30% Load12.7 mV11.0 mV19.7 mV4.6 mVPass
40% Load12.4 mV10.8 mV21.5 mV5.1 mVPass
50% Load12.4 mV11.4 mV21.6 mV5.4 mVPass
60% Load13.2 mV13.2 mV22.6 mV5.5 mVPass
70% Load13.6 mV12.6 mV22.5 mV6.0 mVPass
80% Load13.0 mV13.0 mV19.8 mV6.2 mVPass
90% Load13.3 mV11.5 mV18.1 mV6.2 mVPass
100% Load17.5 mV13.8 mV22.8 mV7.7 mVPass
110% Load19.1 mV14.1 mV24.3 mV8.3 mVPass
Crossload 144.0 mV16.8 mV22.6 mV5.4 mVPass
Crossload 244.0 mV13.3 mV17.1 mV4.1 mVPass
Crossload 332.7 mV13.7 mV31.1 mV3.9 mVPass
Crossload 418.4 mV11.0 mV17.5 mV8.1 mVPass


When you stress the minor rails fully without a load at 12 V, ripple on the 12 V rail is notably increased, which means noise is passed on to the +12 V circuit through the VRMs. In general, ripple is low on all rails, but there is room for improvement at 3.3 V.

Ripple at Full Load



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 4

Next Page »Efficiency
View as single page
May 12th, 2024 08:29 EDT change timezone

New Forum Posts

Popular Reviews

Controversial News Posts