Ripple Measurements

You will see the ripple levels that we measured on the main rails of the Venom 850 W in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements
Akasa Venom Power 850W
Test12 V5 V3.3 V5VSBPass/Fail
20% Load11.5 mV4.5 mV4.3 mV7.7 mVPass
40% Load12.3 mV4.8 mV4.6 mV9.6 mVPass
50% Load13.4 mV5.1 mV4.7 mV11.7 mVPass
60% Load15.9 mV5.3 mV5.1 mV13.5 mVPass
80% Load20.2 mV6.1 mV6.4 mV17.5 mVPass
100% Load26.4 mV6.8 mV8.2 mV22.9 mVPass
110% Load30.5 mV7.2 mV9.3 mV25.4 mVPass
Crossload 110.2 mV4.4 mV4.6 mV6.3 mVPass
Crossload 227.6 mV7.2 mV7.7 mV12.2 mVPass

Ripple suppression is excellent on all rails; that is, even at the 110% load test we conducted. Andyson did a great job in ripple filtering, and the Venom 850 W delivers very clean DC outputs that will contribute well to the longevity of your system's parts. Ripple is, especially on the minor rails, minimal and doesn't exceed 10 mV. This is, undoubtedly, an impressive performance.

Ripple at Full Load

In the following oscilloscope screenshots, you can see the AC ripple and noise that the main rails registered (+12V, 5V, 3.3V, and 5VSB). The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. For all measurements, we set 0.01 V/Div (each vertical division/box equals to 0.01 V) as standard.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2