FSP Hydro PTM Pro 1200 W Review - A Silent Power Factory 1

FSP Hydro PTM Pro 1200 W Review - A Silent Power Factory

Fan Noise »

Efficiency

Using the results we gathered so far, we plotted a chart showing the PSU's efficiency at low loads and loads ranging from 10 to 110 percent of the maximum-rated capacity.




This PSU doesn't take the lead in any of the load regions.

10%–110% Load Testing

These tests reveal the PSU's load regulation and efficiency levels under high ambient temperatures, and show how the fan-speed profile behaves under harsh operating conditions.

Load Regulation & Efficiency Testing Data - FSP Hydro PTM Pro 1200W
Test12 V5 V3.3 V5VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoiseTemp
(In/Out)
PF/AC
Volts
10% Load8.130A1.990A1.974A0.993A120.015W88.744%0 RPM<6.0 dB(A)45.59°C0.855
12.104V5.026V3.346V5.038V135.238W40.72°C230.24V
20% Load17.297A2.987A2.963A1.195A240.059W92.334%0 RPM<6.0 dB(A)46.27°C0.938
12.092V5.022V3.341V5.024V259.989W40.89°C230.25V
30% Load26.762A3.487A3.464A1.396A359.366W93.382%0 RPM<6.0 dB(A)47.84°C0.965
12.081V5.019V3.336V5.013V384.833W41.66°C230.26V
40% Load36.341A3.989A3.964A1.599A479.740W93.660%781 RPM22.2 dB(A)41.75°C0.976
12.067V5.015V3.332V5.004V512.212W48.59°C230.25V
50% Load45.578A4.991A4.964A1.804A599.869W93.686%782 RPM22.2 dB(A)42.15°C0.981
12.053V5.010V3.326V4.990V640.296W49.65°C230.24V
60% Load54.819A5.994A5.965A2.000A719.953W93.323%787 RPM22.3 dB(A)42.63°C0.985
12.043V5.007V3.320V4.976V771.464W50.59°C230.25V
70% Load64.065A6.998A6.971A2.218A839.760W93.045%1065 RPM31.3 dB(A)43.42°C0.986
12.029V5.003V3.315V4.961V902.532W51.69°C230.25V
80% Load73.385A8.002A7.978A2.428A960.201W92.691%1297 RPM37.0 dB(A)44.34°C0.985
12.016V4.999V3.309V4.945V1035.917W53.14°C230.25V
90% Load83.064A8.511A8.475A2.432A1079.533W92.334%1519 RPM41.2 dB(A)45.25°C0.985
12.003V4.995V3.304V4.935V1169.158W54.73°C230.25V
100% Load92.604A9.019A9.004A3.056A1199.961W91.869%1787 RPM45.1 dB(A)46.06°C0.984
11.989V4.992V3.299V4.910V1306.161W56.04°C230.25V
110% Load102.728A9.026A9.014A3.062A1319.997W91.414%2054 RPM48.4 dB(A)46.53°C0.983
11.976V4.988V3.295V4.900V1443.984W57.41°C230.25V
Crossload 10.102A14.004A13.997A0.000A118.017W85.034%814 RPM23.3 dB(A)42.03°C0.859
12.092V5.018V3.323V5.046V138.788W49.02°C230.26V
Crossload 2100.013A1.000A1.001A1.000A1212.937W92.210%1739 RPM44.6 dB(A)45.71°C0.984
11.995V4.999V3.315V4.964V1315.401W56.54°C230.25V

High operating temperatures are not a problem, and load regulation is within 1% at +12 V and 5 V. The competition achieves tighter load regulation on all rails, however. I would like to see higher PF readings, too.

Light Load Testing

In the following tests, we measure the PSU's efficiency at loads significantly lower than 10 percent of the maximum capacity (the lowest load the 80 PLUS standard measures). This is important for representing when a PC is idle with its power-saving features turned on.

Efficiency at Low Loads - FSP Hydro PTM Pro 1200W
Test #12 V5 V3.3 V5 VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoisePF/AC
Volts
12.881A0.497A0.492A0.198A40.041W76.667%0 RPM<6.0 dB(A)0.591
12.111V5.029V3.351V5.061V52.227W230.27V
24.104A0.995A0.983A0.396A59.992W82.369%0 RPM<6.0 dB(A)0.701
12.109V5.028V3.350V5.053V72.833W230.26V
35.334A1.493A1.477A0.595A80.034W85.435%0 RPM<6.0 dB(A)0.773
12.107V5.027V3.349V5.048V93.678W230.27V
46.565A1.989A1.972A0.794A100.066W87.418%0 RPM<6.0 dB(A)0.822
12.104V5.027V3.347V5.043V114.468W230.26V

Efficiency results in this load range are satisfactory.

Ultra-light Load Testing

The applied load in this test is only 10 W for PSUs with 500 W and less capacity. We dial in 2% of the maximum-rated capacity for all other PSUs. We only run this test with 115 V input.

Efficiency at Low Loads - FSP Hydro PTM Pro 1200W
Test #12 V5 V3.3 V5 VSBPower
(DC/AC)
EfficiencyFan SpeedPSU NoisePF/AC
Volts
11.801A0.260A0.260A0.054A24.250W66.222%0 RPM<6.0 dB(A)0.839
12.104V5.025V3.351V5.070V36.619W115.14V

While efficiency isn't quite there with this PSU, the platform can achieve 70% efficiency with 2% load, which is what the newest ATX specification requires. Introducing a new PSU that isn't fully compatible with the current ATX specification is a great shame.

5VSB Efficiency

5VSB Efficiency - FSP Hydro PTM Pro 1200W
Test #5VSBPower (DC/AC)EfficiencyPF/AC Volts
10.100A0.508W62.331%0.019
5.078V0.815W230.27V
20.250A1.270W74.838%0.039
5.077V1.697W230.27V
30.550A2.787W80.479%0.077
5.066V3.463W230.27V
41.000A5.052W82.630%0.130
5.052V6.114W230.27V
51.500A7.571W84.132%0.181
5.048V8.999W230.27V
63.000A15.052W83.664%0.290
5.017V17.991W230.27V



The 5VSB rail is very efficient. Expect even higher efficiency with 115 V input.

Power Consumption in Idle and Standby

Idle / Standby - FSP Hydro PTM Pro 1200W
Mode12 V5 V3.3 V5VSBPower (AC)PF/AC Volts
Idle12.105V5.024V3.352V5.075V9.977W0.184
230.3V
Standby0.218W0.005
230.3V

Vampire power with 230 V input is high. I expect a reading below 0.15 W here.
Next Page »Fan Noise
View as single page
Apr 26th, 2024 09:29 EDT change timezone

New Forum Posts

Popular Reviews

Controversial News Posts