Ripple Measurements

You will see the ripple levels we measured on the rails of the RM650i in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements - Corsair RM650i
Test12 V5 V3.3 V5VSBPass/Fail
10% Load4.5 mV5.2 mV5.3 mV4.4 mVPass
20% Load5.6 mV5.6 mV5.7 mV4.8 mVPass
30% Load6.8 mV9.1 mV7.0 mV8.0 mVPass
40% Load7.1 mV10.4 mV8.6 mV10.3 mVPass
50% Load7.5 mV6.3 mV8.3 mV6.4 mVPass
60% Load7.9 mV6.4 mV7.6 mV6.9 mVPass
70% Load8.0 mV6.7 mV7.4 mV7.4 mVPass
80% Load8.9 mV7.0 mV8.7 mV7.7 mVPass
90% Load10.0 mV7.2 mV8.4 mV8.2 mVPass
100% Load12.3 mV8.9 mV10.4 mV9.5 mVPass
110% Load14.4 mV9.0 mV11.0 mV10.4 mVPass
Crossload 16.8 mV7.5 mV8.4 mV6.6 mVPass
Crossload 212.0 mV8.4 mV9.9 mV8.1 mVPass
Ripple suppression is jaw dropping! This unit is easily capable of competing with Super Flower's high-end implementations. We simply couldn't ask for better results here.

Ripple at Full Load

You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2