Ripple Measurements

You will see the ripple levels we measured on the rails of the SF-750F14EG in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements - Super Flower SF-750F14EG
Test12 V5 V3.3 V5VSBPass/Fail
10% Load4.4 mV3.9 mV5.5 mV5.2 mVPass
20% Load6.0 mV4.2 mV5.4 mV4.9 mVPass
30% Load6.9 mV4.4 mV6.3 mV5.3 mVPass
40% Load7.5 mV5.1 mV6.7 mV5.3 mVPass
50% Load8.2 mV5.4 mV5.9 mV5.5 mVPass
60% Load9.3 mV5.7 mV6.1 mV5.8 mVPass
70% Load10.3 mV6.4 mV6.8 mV6.2 mVPass
80% Load10.8 mV6.6 mV6.3 mV7.3 mVPass
90% Load11.1 mV6.9 mV7.0 mV8.0 mVPass
100% Load11.6 mV7.6 mV7.0 mV8.7 mVPass
110% Load12.0 mV7.8 mV7.0 mV8.9 mVPass
Crossload 15.3 mV4.7 mV6.3 mV11.0 mVPass
Crossload 211.1 mV7.4 mV6.8 mV7.0 mVPass
Super Flower's platform delivers outstanding ripple-suppression results. We do believe that the caps on the modular cables could easily be left out. This platform offers incredibly clean outputs as is, which means several mV more wouldn't curtail its performance at all.

Ripple at Full Load

You can see the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB) in the following oscilloscope screenshots. The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. We set 0.01 V/Div (each vertical division/box equals 0.01 V) as the standard for all measurements.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2