Friday, August 2nd 2019

EK Releases EK-Leak Tester - a Superior Leak Testing Solution

EK the premium liquid cooling gear manufacturer is releasing the EK-Leak Tester. A fast and safe way of testing for possible leaks in your liquid cooling loop. While traditional leak testing works, it requires hours before very small leaks are detected and then things can get messy. The EK-Leak Tester does the job way better!

The main body is a solid piece of CNC machined aluminium. One end is fitted with a revolvable male G1/4" connection port so it can be directly screwed onto any standard port in your liquid cooling loop. The gauge is custom made for liquid cooling loop testing purposes, which clearly marks the safe pressure for testing. The other side of the tester is hooked up with a valve that will make sure no air is escaping through the tester unit. The small pump for pressurizing the loop is also included. However, for a maximum safety effect, EK suggests reaching a pressure you want for testing and leaving the tester on for at least 15 minutes. If no pressure drop occurs and the gauge remains on the same spot, you're good to go.
In order to prevent damage of your liquid cooling loop, keep the pressure in the predefined zone only, as marked on the gauge. Please read the user manual before using the EK-Leak Tester!

The EK-Leak Tester is assembled in Slovenia, Europe and it is readily available for purchase through the EK Webshop and Partner Reseller Network for the manufacturer suggested retail price (MSRP) of 34.90€ with VAT included.
Add your own comment

34 Comments on EK Releases EK-Leak Tester - a Superior Leak Testing Solution

#26
Ferrum Master
What's with the Imperial vs Metric trolling? Are we 13?
Posted on Reply
#27
Jism
jsfitz54Same way a mechanic can pressure test an automobile radiator and cooling system.

Today the wheel was reinvented! Oh wait...:rolleyes:
Its time saving.
Posted on Reply
#28
EarthDog
14 psi isnt in the green zone. ;)

Range is about 7-10 psi.
Posted on Reply
#29
Amite
I use toilet paper
Posted on Reply
#31
jaggerwild
run the pump without the board being powered on, no harm no foul. Detect a leaky, shout it off start ova. No power to the board it can get wet all day long and work fine.
Posted on Reply
#32
PR0PH3CY
v12dockI'm pretty sure you could make one these from parts at a hardware store for $10.
Then do it. You can also build the entire watercooling loop, rad, block and all from junk yard parts. Fantastic. Pat yourself on the back.
Posted on Reply
#33
EarthDog
grumpyBunch of Muppets with lack of for sight.

Go look at your wet fitting on your boiler they all have O rings but also a restraining clip because the pipework is under pressure 2 to 3 bar.
I wonder why they add restraining clips. Maybe because it would be stupid to rely on only the pressure generated from the O ring thumb tight threads.
This is a bad idea and anyone who would use such a thing needs to pull out all the restraining clips from their boiler.
Must not need them.

It amazes me people are actually considering buying this (tool)
Its a risk that isn't worth taking.
If there is a leak the fluid will lubricate the O ring increasing the risk it sliding off the pipe.
Has to be the worst idea i have seen in a long long time and yet people are praising the idea.
Just mind boggling to me.

If you do use this be sure your loop is empty..................
What are you going on about? You dont think this device was tested to work with their products as they described?

If these posts are legit, sounds like you're a fear monger at best. You arent even posting pics of ek parts, but random O rings on....????

The bottom line is if you use this properly, it will work as described. If you put too much pressure through it, your doomsday scenario could happen.
Posted on Reply
#34
DaedalusHelios
SteevoWe use this kind of thing to test cooling systems and refrigerant systems. Air has a lower viscosity than coolant so any leak will show up sooner with a gas than liquid.
Yeah, but that price is excellent for a solution like this. In process engineering, way pay many magnitudes more than this for equivalent tools. Calibrated flow meters are costing us half the value of my house.
Posted on Reply
Add your own comment
Nov 24th, 2026 04:17 CST change timezone

New Forum Posts

Popular Reviews

TPU on YouTube

Controversial News Posts