In Win GreenMe 750 W Review 2

In Win GreenMe 750 W Review

Performance Rating & Performance per Dollar »

Ripple Measurements

You will see the ripple levels we measured on the main rails of the GreenMe 750 in the following table. The limits are, according to the ATX specification, 120 mV (+12V) and 50 mV (5V, 3.3V, and 5VSB).

Ripple Measurements
In Win GreenMe-750
Test12 V5 V3.3 V5VSBPass/Fail
20% Load15.3 mV30.9 mV23.6 mV10.3 mVPass
40% Load19.9 mV33.8 mV25.7 mV16.0 mVPass
50% Load21.9 mV34.6 mV29.1 mV14.7 mVPass
60% Load24.8 mV36.3 mV28.7 mV16.1 mVPass
80% Load39.6 mV36.4 mV27.3 mV16.3 mVPass
100% Load52.3 mV38.9 mV24.5 mV17.1 mVPass
110% Load57.9 mV39.7 mV26.3 mV18.3 mVPass
Crossload 114.2 mV30.1 mV19.7 mV11.3 mVPass
Crossload 247.7 mV33.3 mV23.1 mV13.1 mVPass

Ripple suppression at +12V is decent for a mainstream unit, but we are sensitive to this matter and want to see ripple below 40 mV irregardless of the PSU's cost/category. The 5V rail's ripple was on the high side, but all other rails performed rather well here.

Ripple at Full Load

In the following oscilloscope screenshots shows the AC ripple and noise the main rails registered (+12V, 5V, 3.3V, and 5VSB). The bigger the fluctuations on the oscilloscope's screen, the bigger the ripple/noise. For all measurements, we set 0.01 V/Div (each vertical division/box equals 0.01 V) as standard.



Ripple at 110% Load



Ripple at Crossload 1



Ripple at Crossload 2

Next Page »Performance Rating & Performance per Dollar