Monday, August 4th 2025

Goldenmate Introduces Next-Gen UPS Systems with LiFePO4 Batteries

As modern homes and small businesses become increasingly dependent on connected devices and 24/7 digital access, the risks of sudden power outages-such as data loss, hardware damage, and operational disruption-are more critical than ever. Goldenmate, a brand committed to intelligent power solutions, has launched a next-generation line of UPS (Uninterruptible Power Supply) systems powered by lithium iron phosphate (LiFePO4) technology. These systems ensure consistent, secure backup power across essential devices, including network systems, workstations, and home servers.

Whether it's a home office or a small studio, Goldenmate UPS units provide instant response when power drops, keeping key electronics operational without interruption.
Instant Switching Protects Critical Systems, Including NAS Units
Goldenmate UPS models offer millisecond-level transfer time, enabling seamless switch-over from grid power to battery backup during blackouts or surges. This ensures zero disruption to:
  • Desktop computers, monitors, routers
  • Surveillance cameras and smart home hubs
  • NAS (Network Attached Storage) systems - for protecting valuable personal data
  • POS systems and audio/visual workstations
  • Educational and medical support devices
For tech-savvy users and home offices relying on NAS for backups, remote file access, or media streaming, even brief power failures can lead to system corruption or data loss. Goldenmate UPS devices are specifically engineered to provide consistent voltage and clean shutdown time, helping preserve file systems and prolong device lifespan.

Built on Safe, Long-Life LiFePO4 Technology
Compared to conventional lead-acid UPS products, Goldenmate's UPS systems use LiFePO4 batteries, offering major advantages in safety, longevity, and total cost of ownership:
  • 5000+ deep charge cycles - ensuring stable, long-term performance
  • Enhanced thermal and chemical safety - reducing the risk of overheating or fire
  • Smart Battery Management System (BMS) - prevents overvoltage, short circuit, and over-discharge
  • Low maintenance - with a 10+ year expected service life
Users benefit from safer operation and reduced battery replacement frequency, ideal for installations that run 24/7 or require high data integrity.

Designed for Flexible Applications
Goldenmate UPS models come in a range of output capacities, tailored to specific user needs:
  • 1000 VA / 600 W - For home routers, small PCs, and NAS protection
  • 1000 VA / 800 W - Suits streaming gear, POS systems, and media centers
  • 1500 VA / 1000-1200 W - For schools, clinics, small server rooms
  • 2000 VA / 1600 W - Designed for complex workstations and industrial use
All units are compact, plug-and-play, and easy to install, with built-in surge protection and reliable internal safety systems.

"At Goldenmate, we believe that digital reliability starts with uninterrupted power," said a Goldenmate spokesperson. "Our UPS solutions not only bridge power gaps - they actively protect the systems people trust to store, stream, and secure what matters most."

Source: Goldenmate
Add your own comment

80 Comments on Goldenmate Introduces Next-Gen UPS Systems with LiFePO4 Batteries

#26
Shrek
They claim 10+ years life and then I wonder if the electrolytic capacitors in the support circuit will last much longer.

i.e. does changing the batteries make any sense at that point?
Posted on Reply
#27
remixedcat
Is goldenmate like the JobMate (tools) of UPS??
Posted on Reply
#28
EsaT
trsttteThat's some meaningless marketing comparison right there.

4) lol
5) will this company still exist in 5 years? eaton also offers 5 years on lithium UPSs up to 3kVA.
Eaton 5P serie actually has display with physical four button control interface to access some settings, measurements and fault log.
So what this has is very basic LCD.
Bill_BrightFTR - I never buy UPS replacement batteries from the UPS maker for the very reason you mention. They always charge WAY more for the same batteries you can find cheaper elsewhere...
Note today one distributor will price high with free shipping and the next day price low but with additional shipping charges added. So be sure to factor in shipping, which can be significant, but sometimes free.
For EU Polish TME has good shipping costs, or at least had to Finland little short year ago for three 12V 9AH batteries.
Also packaging was extremely impressive.
Every battery had bubble wrap around it and then that bundle of them was put into (rather oversized) box surrounded by plastic bags filled with some kind initially soft but hardening cushioning foam.
ShrekThey claim 10+ years life and then I wonder if the electrolytic capacitors in the support circuit will last much longer.
Doesn't really matter because of 5 year warranty.

But that's where active cooling or design allowing heat/warmed air rise convectively out from some grille would help.
Some APC Back-UPS ESes are basically designed to bake (cheap) capacitors dead in closed heat inside insulating plastic box.
Posted on Reply
#29
remixedcat
EsaTSome APC Back-UPS ESes are basically designed to bake (cheap) capacitors dead in closed heat inside insulating plastic box.
Avoid those at all costs too went thru 3 of the newer ones that are like this

Apc was ok to deal with but these kept kicking the bucket over and over. And when they do you can smell it from a mile away!! My whole house stank for days!!

Posted on Reply
#30
Bill_Bright
For the record, I would not buy a 425VA (≈255W) UPS (regardless the quality) to support much of anything, except maybe the base station for my home phone system. Certainly not a PC.
Posted on Reply
#31
R-T-B
AsRockAnd you had them how long ?. 1 year hmm, let me know in 5 years.
I'd worry more about the UPS then the cells. It's not like they are lying on longevity, LiFePO4's have been around the block enough to prove that.
Bill_BrightFor the record, I would not buy a 425VA (≈255W) UPS (regardless the quality) to support much of anything, except maybe the base station for my home phone system. Certainly not a PC.
I was going to say, that's not good for much more than a modem and maybe a small network appliance, like a switch. The runtime will otherwise be so poor you won't even be able to save in many cases, or worse, it'll just cut power from overload.
tfp[Citation needed]

I only say that half in jest, the real question is can you replace these batteries and it looks like no and how much do replacements actually cost. For now I will stick with led acid that cost me 20 bucks ever 3+ years vs buying new for multi hundreds every 8 to 10.
From a "per cycle" perspective they absolutely are. From a per cell perspective? Not quite.
Posted on Reply
#32
tfp
R-T-BI'd worry more about the UPS then the cells. It's not like they are lying on longevity, LiFePO4's have been around the block enough to prove that.


I was going to say, that's not good for much more than a modem and maybe a small network appliance, like a switch. The runtime will otherwise be so poor you won't even be able to save in many cases, or worse, it'll just cut power from overload.


From a "per cycle" perspective they absolutely are. From a per cell perspective? Not quite.
Considering my backups kick on for a few minutes less than 10 times a year per cycle is not the right measurement. The measurement is cost of ownership over time and can I replace the battery. If it cost 2x the price as a comparable led-acid system and i replace the battery once in 10 years because I don't use them the led-acid setup wins more so if I can keep doing that for 15 years before I have to buy all new.

Now if lithium setup is the same price and I can replace the battery for about the same cost sure I'll switch over when what I have dies.
Posted on Reply
#33
R-T-B
tfpConsidering my backups kick on for a few minutes less than 10 times a year per cycle is not the right measurement. The measurement is cost of ownership over time
Well LiFePO4 wins hands down there too. Not sure about this particular UPS but the chemistry at least has a 10 year average lifespan vs 3-5 for lead acid.
Posted on Reply
#34
tfp
R-T-BWell LiFePO4 wins hands down there too. Not sure about this particular UPS but the chemistry at least has a 10 year average lifespan vs 3-5 for lead acid.
No it does not

www.amazon.com/GOLDENMATE-Protector-Batteries-Interactive-Sinewave/dp/B0DQ4RH4SL/ref=sr_1_4?th=1
Goldenmate 1500VA UPS 340 with 15% off discount

www.amazon.com/CyberPower-CP1500PFCLCD-Sinewave-Outlets-Mini-Tower/dp/B00429N19W/ref=sr_1_3
CyberPower 1500VA 240 with out a discount.

www.newegg.com/cyberpower-cp1500avrlcd3/p/N82E16842102441
Here is a cheaper version for 200 at the Egg.


At a 100 dollar prices difference I can buy 2.5 pairs of replacement battery's lasting me 10 to 15 years, at 140 that is 3.5 pairs of battery's lasting me 15 to 20 years. Unless they pay me to replace the Goldenmate's battery at 10 years I'm head in cost assuming that Goldenmate's UPS battery can be replaced. If the battery is not replaceable it's another 300 bucks for 10 more years because I have to buy a full new UPS. The math just does not check out yet.
Posted on Reply
#35
R-T-B
tfpNo it does not
I was talking the chemistry in general as I stated, not this goldenmate example. I pretty much stated this goldenmate isn't the best UPS deal a few times.
Posted on Reply
#36
tfp
No the measurement is total cost of ownership, it does not win for now.
Posted on Reply
#37
Shrek
Have you included the price of your present UPS?
Posted on Reply
#38
tfp
ShrekHave you included the price of your present UPS?
Yes that's why listed the cost of the UPS in the post above. If I included the price I paid it would have been more like 160 for the 1500VA and the batteries are still 20 bucks each. In no reasonable reality is it cheaper to replace what you already have with one of these new liFePO4 setups until the old UPS dies that's why I was stating if buying new because that is the best case reason for going liFePO4. Again it still does not make sense financially today.

Would it help if I said I was for the long term move to liFePO4 but I am able to do simple arithmetic?
Posted on Reply
#39
Shrek
Well, yes and no, using the prices from amazon
  • GoldMate 1000VA/800W $190
  • GoldMate 1500VA/1000W $340
So, I would be tempted to compare 800W units rather than 1000W units
Posted on Reply
#40
tfp
Sure if you are not looking to replace what you already have completely. I have a 1500VA right now, well I really have two so if some day I'm looking to downgrade GREAT!

Frankly you should be showing me this link; for 5 bucks more per replacement battery I'd be happy to move my current 1500VA system over when the time comes assuming this is a "drop-in" replacement.
www.amazon.com/GOLDENMATE-Lithium-Waterproof-Phosphate-Lighting/dp/B0DJ2L5Z5J?ref_=ast_sto_dp&th=1
Posted on Reply
#41
Shrek
"steady continuous output of up to 7A"

probably makes this battery useless to you
Posted on Reply
#42
Solaris17
Super Dainty Moderator
IMABEARLOLI have two of the 600w units. They are a little skimpy on the UPS features, like no USB monitoring of the UPS unless you get the "pro" or 1000w+ models.

Despite this "announcement", I have owned one of the units for over a year.

The battery chemistry is simply better than lead-acid. Safer, and can be deep-cycled without damaging the battery. The battery has a 10-year service life, and this includes being deeps cycled daily. Current testing on LiFePo4 is that a battery will still have 90% of its manufactured capacity after 1000 cycles. The chemistry is also recyclable, though not quite as efficiently as lead-acid.

So yes, it's logical that the same output and capacity will cost more on this battery chemistry, but you will get a much longer and more reliable service life out of it.
Can you speak to there effectiveness? There was some controversy about the hold up time and I am curious if you have experienced a power outage and well, if it worked for you?
Posted on Reply
#43
tfp
Shrek"steady continuous output of up to 7A"

probably makes this battery useless to you
I don't know, I'm pretty sure the APC/Cyberpower battery are only 2 7.2Ah 12V batteries. I would expect that LiPo at 7Ah would be pretty similar. The 10Ah batteries are 10 bucks more but so are the 9Ah led-acid batteries.
Posted on Reply
#44
Shrek
7A current, not 7Ah capacity

7A implies 84W which is tiny.
Posted on Reply
#45
tfp
Hah yeah I see that now, nice spotting that. 84w at 2x is almost good enough for a laptop.
Posted on Reply
#46
alawadhi3000
tfpNo it does not

www.amazon.com/GOLDENMATE-Protector-Batteries-Interactive-Sinewave/dp/B0DQ4RH4SL/ref=sr_1_4?th=1
Goldenmate 1500VA UPS 340 with 15% off discount

www.amazon.com/CyberPower-CP1500PFCLCD-Sinewave-Outlets-Mini-Tower/dp/B00429N19W/ref=sr_1_3
CyberPower 1500VA 240 with out a discount.

www.newegg.com/cyberpower-cp1500avrlcd3/p/N82E16842102441
Here is a cheaper version for 200 at the Egg.

At a 100 dollar prices difference I can buy 2.5 pairs of replacement battery's lasting me 10 to 15 years, at 140 that is 3.5 pairs of battery's lasting me 15 to 20 years. Unless they pay me to replace the Goldenmate's battery at 10 years I'm head in cost assuming that Goldenmate's UPS battery can be replaced. If the battery is not replaceable it's another 300 bucks for 10 more years because I have to buy a full new UPS. The math just does not check out yet.
It doesn't work that way.

1) A LIFEPO4 battery will last ~10 years if you cycle it daily, a lead acid battery will only last ~6 months if you do the same.
2) The battery in the Cyberpower is 2x 9Ah 12V (2x 108WHr = 216Wh versus 296Wh for the Goldenmate), but the lead acid battery is rated at 20HR whereas the LIFEPO4 is rated at 1HR, the lead acid battery falls on it face when you draw a lot of power from it.

Just to give you an example the Cyberpower will give you 66 minutes at 100W (~110 Wh) versus 142 minutes for the Goldenmate (~236Wh).
The gap becomes bigger with higher loads, at 500W The Cyberpower will give you 10 minutes (~83Wh) versus 28 minutes for the Goldenmate (~236Wh).

BTW the $200 Cyberpower has simulated sinewave inverter, thats why its cheaper.
Posted on Reply
#47
tfp
Yes it does work that way. Unless you have really horrible power no one is using their UPS more then a couple times a year and for a few minutes each time.

Please present data that Goldenmate has a cleaner sinewave then cyberpower.
Posted on Reply
#48
Bill_Bright
alawadhi3000It doesn't work that way.

1) A LIFEPO4 battery will last ~10 years if you cycle it daily, a lead acid battery will only last ~6 months if you do the same.
No. Sorry but that is wrong.

tfp is right.

LifePO4 batteries do not need to by cycled daily. That's silly. Got a link? HOWEVER, they tolerate daily deep cycling very well and that makes them ideal for use in solar powered systems where they provide power to devices throughout each night. But that does NOT increase their expected lifespan - nor does it degrade it.

There's no reason a "properly sized" SLA battery in a UPS would be subjected to that sort of abuse either - even with an unstable grid. Yes, frequent, "deep" discharges under heavy loads will shorten their life. But that still typically results in a good 2 years. But as tfp correctly noted, typical full power outages are rare and rarely involve deep discharging. Thus most SLA batteries in UPS devices last a good 3 to 5 years, or even longer.
alawadhi3000BTW the $200 Cyberpower has simulated sinewave inverter, thats why its cheaper.
And nothing wrong with that. Any decent power supply can easily deal with that without any problems. Have for decades, no reason they can't now. Do NOT risk having this thread locked by instigating another off-topic debate on pure vs simulated UPS, as happened here. That is not what this tread is about. Further discussion on that will be reported.
Posted on Reply
#49
Shrek
I believe he is not saying you have to cycle it, but rather if you did it would still last 10 years.
Posted on Reply
#50
Bill_Bright
ShrekI believe he is not saying you have to cycle it, but rather if you did it would still last 10 years.
:oops: Oops. If @alawadhi3000, you meant "still" will last, then my apologies for misunderstanding. And yes that is correct and one of their advantages for sure.
Posted on Reply
Add your own comment
Nov 27th, 2026 17:35 CST change timezone

New Forum Posts

Popular Reviews

TPU on YouTube

Controversial News Posts