Hardware Unboxed Falls Victim to Melted RTX 5090 Power Connector as Cable Reaches 175°C
Hardware Unboxed has become the latest hardware channel to watch a 12V-2×6 connector melt on an RTX 5090 test bench. The setup paired an ASUS ROG Astral RTX 5090 with a be quiet! Dark Power 13 PSU, and host Steve reportedly only caught the fault after touching the cable and finding it hot enough to burn his hand. A thermal camera later confirmed readings above 150°C, climbing to roughly 175°C under load. A Thermal Grizzly WireView Pro caught the underlying problem immediately: a severe current imbalance where some pins carried almost nothing while a single wire was pulling around 22A. Oddly, the damage turned out to be worse on the PSU side rather than at the GPU.
The cable had fused inside the Dark Power 13's connector and needed pliers to remove, while the card's own connector escaped without visible marks. Hardware Unboxed says the cable was fully seated and isn't blaming the incident on installation. This is far from an isolated case, as this connector is notorious for melting. We have reported RTX 5090 connectors melting even after users apply undervolts and power limits, and reported on at least one instance where an ASRock PSU's thermal cutoff saved a card from a similar fate. Some frustrated modders have gone so far as to solder wires directly to the PCB just to sidestep the connector altogether.
Source:
Hardware Unboxed on YouTube
The cable had fused inside the Dark Power 13's connector and needed pliers to remove, while the card's own connector escaped without visible marks. Hardware Unboxed says the cable was fully seated and isn't blaming the incident on installation. This is far from an isolated case, as this connector is notorious for melting. We have reported RTX 5090 connectors melting even after users apply undervolts and power limits, and reported on at least one instance where an ASRock PSU's thermal cutoff saved a card from a similar fate. Some frustrated modders have gone so far as to solder wires directly to the PCB just to sidestep the connector altogether.


93 Comments on Hardware Unboxed Falls Victim to Melted RTX 5090 Power Connector as Cable Reaches 175°C
@jonnyGURU
@Dr. Dro
Get this man a AMD APU STAT!
The card still melted despite it being an Astral, along with a Wireview, the connector is the issue and IMO these cables are just a bandaid fix for the real problem.
Let me clarify that they said that the PSU was at fault, and of course they are going to say it wasn't user error, but without seeing everything up close, that leaves an out for the warranty replacement stuff if they have to do that
Cable manufacturers warn that to avoid such problems, it is not allowed to bend the cable closer than 30 mm to the 12VHPWR connector. I advise you to use 12VHPWR, not the new 12V-2x6. Cable thickness 16 AWG. 1.31 x 6 = 7.86 mm² of total cross-section on the positive line (and the same on the negative). Length 0.75 m. Withstands 60-70 A of long-term load without critical heating of the cores. Based on power P = I x U. 70 A x 12 V = 840 Watts. With short-term peak loads, even more.
It is absolutely unclear what the author of the video expected from the Chinese 18 AWG cable, which he first mocked and then took and burned.
Do they say what cable they were using during this test? Or is it certain the the card was the issue drawing on the wrong pins?
I have a few more cases for the thread I've been maintaining, I'll update it later tonight or tomorrow morning.Bingo. But it's a unfortunate reality, we can only hope next gen cards drop this connector, but I doubt it
And yes, it is a bad CARD DESIGN to allow one cable to carry that load. This is why cards need to have load balancing on board.
Main thing is those cards are running on 48+ volts AND mounted direct to the server board via interposers instead of using cables.
They should have named this the Vegas series. Roll the dice on your 5 grand.